Automated seed loaders for permanent prostate implants are now commercially available. Besides improved radiation safety, these systems offer seed assay capability and ease of needle loading, making preplanned as well as intra-operative implant procedures more time-efficient. The Isoloader (Mentor Corp., CA) uses individual I125 seeds (SL-125 ProstaSeed) loaded in up to 199 chambers inside a shielded cartridge. The unit performs seed counting and calibration using a builtin solid-state detector. In order to evaluate the reproducibility and accuracy of the calibration process, two test cartridges were measured with the Isoloader itself and compared with a well-type ionization chamber (HDR-1000Plus, Standard Imaging). The air kerma strength measurements for all seeds using the Isoloader had a standard deviation of about 2.7%. For the eight seeds assayed more intensively using both the Isoloader and well chamber, the standard deviations of the measurements for each seed were in the range of 0.8% to 2.8% and 0.6% to 1.3%, respectively. The variation in the Isoloader calibration is attributed to small detector solid angle and bead geometry within seed capsules (verified by radiographs). The reproducibility of the air kerma strength measured by the Isoloader was comparable to that from the well chamber and was clinically acceptable. Seed strength measured with the Isoloader was on average 1% 2% larger than that measured with the well chamber, indicating that the accuracy of the Isoloader was clinically acceptable.
منابع مشابه
Feasibility of calibrating elongated brachytherapy sources using a well-type ionization chamber.
Recently, elongated brachytherapy sources (active length >1 cm) have become commercially available for interstitial prostate implants. These sources were introduced to improve the quality of brachytherapy procedures by eliminating the migration and seed bunching associated with loose seed-type implants. However, the inability to calibrate elongated brachytherapy sources with the Wide-Angle Free...
متن کاملDynamic Dosimetry and Edema Detection in Prostate Brachytherapy - a Complete System
Purpose: Brachytherapy (radioactive seed insertion) has emerged as one of the most effective treatment options for patients with prostate cancer, with the added benefit of a convenient outpatient procedure. The main limitation in contemporary brachytherapy is faulty seed placement, predominantly due to the presence of intraoperative edema (tissue expansion). Though currently not available, the ...
متن کاملA technical evaluation of the Nucletron FIRST system: Conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations
The Fully Integrated Real-time Seed Treatment (FIRST) system by Nucletron has been available in Europe since November 2001 and is being used more and more in Canada and the United States. Like the conventional transrectal ultrasound implant procedure, the FIRST system utilizes an ultrasound probe, needles, and brachytherapy seeds. However, this system is unique in that it (1) utilizes a low-dos...
متن کاملProstate Brachytherapy Seed Localization with Gaussian Blurring and Camera Self-calibration
A tomosynthesis-based prostate brachytherapy seed localization method is described. Gaussian-blurred images are computed from a limited number of X-ray images, and a 3-D volume is reconstructed by backprojection. Candidate seed locations are extracted from the reconstructed volume and false positive seeds are removed by optimizing a local cost function. In case where the estimated pose error is...
متن کاملEvaluation of a Novel Thermobrachytherapy Seed for Concurrent Administration of Brachytherapy and Magnetically Mediated Hyperthermia in Treatment of Solid Tumors
Concurrent hyperthermia and radiation therapy in treatment of cancer show a strong evidence of a synergistic enhancement. We designed a new self-regulating Thermo-Brachytherapy seed, which serves as a source of both radiation and heat for concurrent administration of brachytherapy and hyperthermia. The Thermo-Brachytherapy seed has a core of ferromagnetic material which produces heat when subje...