Reduction of the available area for aqueous humor outflow and increase in meshwork herniations into collector channels following acute IOP elevation in bovine eyes.

نویسندگان

  • Stephanie A Battista
  • Zhaozeng Lu
  • Sara Hofmann
  • Thomas Freddo
  • Darryl R Overby
  • Haiyan Gong
چکیده

PURPOSE To understand how hydrodynamic and morphologic changes in the aqueous humor outflow pathway contribute to decreased aqueous humor outflow facility after acute elevation of intraocular pressure (IOP) in bovine eyes. METHODS Enucleated bovine eyes were perfused at 1 of 4 different pressures (7, 15, 30, 45 mm Hg) while outflow facility was continuously recorded. Dulbecco PBS + 5.5 mM glucose containing fluorescent microspheres (0.5 mum, 0.002% vol/vol) was perfused to outline aqueous outflow patterns, followed by perfusion-fixation. Confocal images were taken along the inner wall (IW) of the aqueous plexus (AP) in radial and frontal sections. Percentage effective filtration length (PEFL; IW length exhibiting tracer labeling/total length of IW) was measured. Herniations of IW into collector channel (CC) ostia were examined and graded for each eye by light microscopy. RESULTS Increasing IOP from 7 to 45 mm Hg coincided with a twofold decrease in outflow facility (P < 0.0001), a 33% to 57% decrease in PEFL with tracer confined more to the vicinity of CC ostia, progressive collapse of the AP, and increasing percentage of CC ostia exhibiting herniations (from 15.6% +/- 6.5% at 7 mm Hg to 95% +/- 2.3% at 30 mm Hg [P < 10(-4)], reaching 100% at 45 mm Hg). CONCLUSIONS Decreasing outflow facility during acute IOP elevation coincides with a reduction in available area for aqueous humor outflow and the confinement of outflow to the vicinity of CC ostia. These hydrodynamic changes are likely driven by morphologic changes associated with AP collapse and herniation of IW of AP into CC ostia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aqueous Dynamics and Surgical Restoration of the Natural Outflow System

IOP is maintained within a normal range by a dynamic balance between aqueous humor production by the ciliary epithelium and drainage through two pathways the conventional outflow pathway and the uveoscleral pathway. However, the conventional outflow pathway is the major aqueous drainage pathway through which 70–90% of aqueous humor exits and consists of the trabecular meshwork (consisting of th...

متن کامل

Aqueous outflow - A continuum from trabecular meshwork to episcleral veins

In glaucoma, lowered intraocular pressure (IOP) confers neuroprotection. Elevated IOP characterizes glaucoma and arises from impaired aqueous humor (AH) outflow. Increased resistance in the trabecular meshwork (TM), a filter-like structure essential to regulate AH outflow, may result in the impaired outflow. Flow through the 360° circumference of TM structures may be non-uniform, divided into h...

متن کامل

The Juxtacanalicular Region of Ocular Trabecular Meshwork: A Tissue with a Unique Extracellular Matrix and Specialized Function.

The trabecular meshwork (TM) is a filter-like tissue located in the anterior segment of the eye. It is composed of a series of fenestrated beams through which aqueous humor flows to exit the anterior chamber via Schlemm's canal. The primary function of the TM is to regulate the flow of aqueous humor in order to establish intraocular pressure (IOP). Dysregulated aqueous humor outflow causes elev...

متن کامل

Biol. Pharm. Bull. 28(12) 2189—2196 (2005)

for primary open angle glaucoma (POAG), and lowering IOP is currently the only treatment available for the management of POAG. The conventional route of aqueous humor outflow through trabecular meshwork (TM) and Schlemm’s canal (SC) is generally thought to be the major pathway for the drainage of aqueous humor from the eye. Impaired drainage through the conventional outflow pathway is believed ...

متن کامل

3D finite element model of aqueous outflow to predict the effect of femtosecond laser created partial thickness drainage channels.

BACKGROUND AND OBJECTIVES Partial thickness drainage channels can be created with femtosecond lasers in the translucent sclera for the potential treatment of glaucoma. We present a 3D finite element model (FEM) that can predict the effect of these channels on aqueous humor (AH) outflow and intraocular pressure (IOP). STUDY DESIGN/MATERIALS AND METHODS A 3D model was developed based on a 2D mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 49 12  شماره 

صفحات  -

تاریخ انتشار 2008