Comparing the full-threshold and Swedish interactive thresholding algorithms for short-wavelength automated perimetry.
نویسندگان
چکیده
PURPOSE To compare the Swedish interactive thresholding algorithm (SITA) with the full-threshold (FT) strategy for short-wavelength automated perimetry (SWAP). METHODS One eye of 286 patients with glaucomatous optic neuropathy (GON) and 289 age-matched participants without GON from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES) were classified with optic disc stereophotographs taken within 6 months of visual field testing, conducted within a 3-month period. Six parameters were derived per test, including pattern standard deviation (PSD) and the number of pattern deviation plot (PDP) points triggered at <1%. Receiver-operating characteristic (ROC) analysis equated the tests for specificity (80%, 90%, and 95%). Sensitivities of parameters with the highest area under the curve (AUC) and STATPAC (Carl Zeiss Meditec, Inc., Dublin, CA) PSD were compared. Agreement, severity, and test duration between algorithms were assessed. RESULTS Sensitivities were not different between algorithms using PSD. With PDP <1%, SWAP-FT was more sensitive (35%) than SWAP-SITA (29%) at 95% specificity (P<0.05). Sensitivity and specificity using the STATPAC PSD at 95% (P<5%) and 99.5% (P<0.05%) was similar between algorithms. Severity correlated significantly between algorithms (P<0.001), although there was bias for SWAP-SITA to suggest more severe loss. SWAP-SITA required significantly less test time than did SWAP-FT (P<0.001). Mean differences in PSD, PDP <1%, and MD between algorithms were not clinically significant. CONCLUSIONS Both algorithms performed similarly when equated for specificity. The reduced test duration makes SWAP-SITA the better choice. Testing with both algorithms within a short period is recommended for confirmation of results when switching from FT to SITA.
منابع مشابه
A new rapid threshold algorithm for short-wavelength automated perimetry.
PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...
متن کاملComparison of Different Analytic Algorithms for Interpretation of the Swedish Interactive Threshold Algorithm Strategy
OBJECTIVE To compare 4 analytic algorithms for interpretation of the Swedish Interactive Threshold Algorithm. INTRODUCTION Analytic algorithms were initially developed for interpretation of standard automated perimetry (using a full threshold strategy). The Swedish interactive threshold algorithm is a novel strategy that was developed to shorten test duration. METHODS One hundred forty-thre...
متن کاملVariability in short-wavelength automated perimetry among peri- or postmenopausal women: a dependence on phyto-oestrogen consumption?
PURPOSE To determine whether the hill of vision for Short-Wavelength Automated Perimetry (SWAP) is shallower for women who consume phyto-oestrogen-rich foods than for women who do not. METHODS Visual field data were compared for two groups of healthy amenorrhoeic women 48-69 years-old with normal vision and not using hormone replacement: (1) 24 subjects who reported consuming soy and/or flax ...
متن کاملNormal intersubject threshold variability and normal limits of the SITA SWAP and full threshold SWAP perimetric programs.
PURPOSE To compare intersubject variability and normal limits of threshold values between the new Swedish interactive test algorithm short wavelength automated perimetry (SITA SWAP) and the older Full Threshold SWAP programs (Carl Zeiss Meditec, Dublin, CA). METHODS Normal reduction of differential light sensitivity with age, age-corrected thresholds, intersubject variability, and normal limi...
متن کاملBetween-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.
PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 4 شماره
صفحات -
تاریخ انتشار 2009