A study of the bone healing kinetics of plateau versus screw root design titanium dental implants.

نویسندگان

  • Gary Leonard
  • Paulo Coelho
  • Ioannis Polyzois
  • Leo Stassen
  • Noel Claffey
چکیده

OBJECTIVE This study was designed to compare the bone healing process around plateau root from (PRF) and screw root from (SRF) titanium dental implants over the immediate 12 week healing period post implant placement. MATERIAL AND METHODS 32PRF and 32SRF implants were placed in 8 beagle dogs at 12, 8, 5 and 3 weeks prior to enthanisation using a bilaterally balanced distribution. Undecalcified ground sections were prepared from the biopsies taken and histometric measurements of bone implant contact (BIC) and bone area fraction occupancy (BAFO) were made on the middle 5 mm portion of each 8 mm implant root length. RESULTS The analysis showed that although measurements of bone to implant contact (BIC) and bone area fraction occupancy (BAFO) tended to be greater for the SRF implants at all four time points, the differences in measurements between implant types did not reach statistical significance (P=0.07, P=0.06). The effect of time on BIC and BAFO was found to be strongly significant for both implant types thus indicating a statistically significant increase in BIC and BAFO overall with time (P=0.004, P=0.002). Furthermore, both PRF and SRF implants behaved similarly over time with measurements of BIC and BAFO progressing in parallel. Histomorphologic analysis of these sections demonstrated the prominent role of woven bone (callus) in the bone healing process around PRF implants. CONCLUSION The results can be interpreted to indicate a comparable development of secondary stability for both PRF and SRF implant designs. However, as these parameters reflect the structural connection between implant and bone and not the functional properties of the bone to implant interface, they cannot be regarded as comprehensive measures of osseointegration. This particularly relevant given the reduced load bearing capacity of woven bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant Surface Micro-Design

The application of implants for dental and orthopedic surgery has increased rapidly within the past few decades. In craniomaxillofacial surgery, different implant systems have been applied, for example, for dental and bone replacement or osteosynthesis plates and screws. These implants may be made of pure titanium or a titanium alloy, usually titanium-aluminumvanadium (Ti-6Al-4V). The surface c...

متن کامل

ارزیابی مقایسه ای رشد استخوان اطراف اندوایمپلنت های دندانی با و بدون پوشش هیدروکسی آپاتیت

Bone osseointegration around dental implant can cause earlier stabilization and fixation of implant and reduce healing time. Hydroxyapatite coating can affect bone osseointegration and enhance its rates. The aim of this study was comparison of osseointegration between plasma sprayed hydroxyapatite coated and uncoated dental implants in cats. Four endodontic implants including, vitallium and two...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Guided bone regeneration around titanium plasma-sprayed, acid-etched, and hydroxyapatite-coated implants in the canine model.

BACKGROUND Endosseous dental implants with rough surfaces have been designed to improve early healing, especially in areas of poor bone or insufficient bone quantity. The aim of this study was to histomorphometrically assess the bone-to-implant contact on 3 different rough-surfaced implants following guided bone regeneration. METHODS Mandibular premolars and first molars were extracted in 12 ...

متن کامل

A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks.

STATEMENT OF PROBLEM An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps. PURPOSE The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by ce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2009