Comparison of drug delivery with autoinjector versus manual prefilled syringe and between three different autoinjector devices administered in pig thigh

نویسندگان

  • Robert L Hill
  • John G Wilmot
  • Beth A Belluscio
  • Kevin Cleary
  • David Lindisch
  • Robin Tucker
  • Emmanuel Wilson
  • Rajesh B Shukla
چکیده

Parenteral routes of drug administration are often selected to optimize actual dose of drug delivered, assure high bioavailability, bypass first-pass metabolism or harsh gastrointestinal environments, as well as maximize the speed of onset. Intramuscular (IM) delivery can be preferred to intravenous delivery when initiating intravenous access is difficult or impossible. Drugs can be injected intramuscularly using a syringe or an automated delivery device (autoinjector). Investigation into the IM delivery dynamics of these methods may guide further improvements in the performance of injection technologies. Two porcine model studies were conducted to compare differences in dispersion of injectate volume for different methods of IM drug administration. The first study compared the differences in the degree of dispersion and uptake of injectate following the use of a manual syringe and an autoinjector. The second study compared the spatial spread of the injected formulation, or dispersion volume, and uptake of injectate following the use of five different autoinjectors (EpiPen(®) [0.3 mL], EpiPen(®) Jr [0.3 mL], Twinject(®) [0.15 mL, 0.3 mL], and Anapen(®) 300 [0.3 mL]) with varying needle length, needle gauge, and force applied to the plunger. In the first study, the autoinjector provided higher peak volumes of injectate, indicating a greater degree of dispersion, compared with manual syringe delivery. In the second study, EpiPen autoinjectors resulted in larger dispersion volumes and higher initial dispersion ratios, which decreased rapidly over time, suggesting a greater rate of uptake of injectate than the other autoinjectors. The differences in dispersion and uptake of injectate are likely the result of different functional characteristics of the delivery systems. Both studies demonstrate that the functional characteristics of the method for delivering IM injections impact the dispersion and uptake of the material injected, which could significantly affect the pharmacokinetics and, ultimately, the effectiveness of the drug.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative Bioavailability of a Single Dose of Belimumab Administered Subcutaneously by Prefilled Syringe or Autoinjector in Healthy Subjects

Intravenous belimumab is approved for the treatment of systemic lupus erythematosus; subcutaneous self-administration would enable greater patient access. This study assessed relative bioavailability, tolerability, and safety of 1 subcutaneous dose of self-administered belimumab by healthy subjects using a single-use autoinjector or prefilled syringe. Subjects (randomized 1:1:1:1) self-administ...

متن کامل

Phase 3, open‐label, randomized study of the pharmacokinetics, efficacy and safety of ixekizumab following subcutaneous administration using a prefilled syringe or an autoinjector in patients with moderate‐to‐severe plaque psoriasis (UNCOVER‐A)

BACKGROUND The efficacy of ixekizumab, an anti-interleukin-17A (anti-IL-17A) monoclonal IgG4 antibody, was demonstrated in moderate-to-severe psoriasis patients when administered via prefilled syringe (PFS). OBJECTIVE To evaluate the effect of two drug delivery devices on the pharmacokinetics (PK) of ixekizumab as well as efficacy and safety with both devices. METHODS In the first 12 weeks ...

متن کامل

Evaluation of pharmacokinetics, user handling, and tolerability of peginterferon alfa-2a (40 kDa) delivered via a disposable autoinjector device

BACKGROUND Peginterferon alfa-2a (40 kDa) is currently administered using a prefilled syringe. The peginterferon alfa-2a disposable autoinjector is a new safety-engineered device designed to facilitate injection and reduce the risk of needlestick injuries. The analysis of two open-label Phase I trials evaluated the pharmacokinetics, successful administration, and tolerability of peginterferon a...

متن کامل

An open-label, multicenter study to evaluate the safe and effective use of the single-use autoinjector with an Avonex® prefilled syringe in multiple sclerosis subjects

BACKGROUND The ability to self-inject in patients with multiple sclerosis (MS) has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patients' independence. However, injection anxiety, needle phobia and disease-related disability are major barriers to a patient's ability to self-administer treatment. Use of an autoinjector may improve ...

متن کامل

Patient Evaluation of Satisfaction and Outcomes with an Autoinjector for Self-Administration of Subcutaneous Belimumab in Patients with Systemic Lupus Erythematosus

OBJECTIVE This study assessed patient experiences of using an autoinjector device to self-administer subcutaneous belimumab for the treatment of systemic lupus erythematosus (SLE). Satisfaction, ease and convenience of use, and confidence with the device were assessed, in addition to overall experience with belimumab. METHODS This cross-sectional study was conducted among patients who complet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -