Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation

نویسندگان

  • Farzad Rahmani
  • Hassan Soleimanpour
  • Ali Zeynali
  • Ata Mahmoodpoor
  • Kavous Shahsavari Nia
  • Jafar Rahimi Panahi
  • Sarvin Sanaei
  • Maryam Soleimanpour
  • Robab Mehdizadeh Esfanjani
چکیده

Introduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe airway in intubated patients. On the other hand, excessive increase or decrease in the pressure of TTC's balloon leads into the dangerous complications such as necrosis and/or aspiration. Accordingly, in the present study, we tried to evaluate the most two common fixed volume and pilot balloon palpitation methods to control TTC pressure. Methods: In a prospective cross-sectional study that was carried out in the emergency department of Tabriz Imam Reza hospital upon 194 patients who needed intubation and from April 2015 to June 2016. The patients were randomly allocated into two equal groups. For the first the Pilot Balloon Palpation technique and for the second group 10 cc fixed volume cuff filling technique was assigned. After that, the pressure was checked with manometer and data were analyzed using SPSS software. Results: TTC pressure average in fixed volume group was 44.96±21.77 cmH2O and for palpation group, it was 118.15±22.15 cmH2O. There was a meaningful difference between two groups in terms of cuff inside pressure (P value <0.001) and it was meaningfully lower in fixed volume group than the first one. Conclusion: The present study showed that pilot balloon palpation or fixed volume method was not appropriate methods to assess cuff pressure during intubation and the cuff pressure must be controlled by the manometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Use of pressure volume loop closure to check for endotracheal tube cuff function. Randomized clinical trial.

OBJECTIVE To assess the efficacy of pressure volume loop (PV-L) closure as an indicator of adequate endotracheal tube cuff (ETTc) function, and to compare this with commonly used methods of checking cuff pressure. METHODS We conducted a randomized clinical trial at the Department of Anesthesia, King Abdulaziz University Hospital, Jeddah, Kingdom of Saudi Arabia from October 2011 to February 2...

متن کامل

Automatic endotracheal tube cuff inflator and continuous pressure monitor/controller.

Endotracheal tube cuff pressure over 30 cm of water has been found to occur in about 50% of cases where cuff inflation was performed without monitoring, using pilot balloon palpation, minimal leak, or minimal occlusive volume techniques1. The incidence of post operative respiratory complications such as cough, sore throat, hoarseness, blood-streaked expectoration, and even tracheal stenosis is ...

متن کامل

Endotracheal Tube Cuff Pressure Assessment: Education May Improve but not Guarantee the Safety of Palpation Technique

BACKGROUND Endotracheal Tube Cuff Pressure (ETCP) should be kept in the range of 20 - 30 cm H2O. Earlier studies suggested that ETCP assessment by palpation of pilot balloon results in overinflation or underinflation and subsequent complications such as tracheal wall damage and aspiration. OBJECTIVES The current study aimed to evaluate the effect of an in vitro educational program on the abil...

متن کامل

Effects of user experience and method in the inflation of endotracheal tube pilot balloon on cuff pressure.

CONTEXT Endotracheal tube cuff pressure (ETCP) is recommended to be maintained between 20-30 cm H2O limits. While insufficient inflation of ETC may cause aspirations, over-inflation of it may lead to damage in tracheal epithelium. AIMS We planned to investigate the effects of user experience and cuff pressure inflation method differences following endotracheal tube cuff pressure and complaint...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -