Practical considerations of linear accelerator‐based frameless extracranial radiosurgery for treatment of occipital neuralgia for nonsurgical candidates

نویسندگان

  • Travis R. Denton
  • Lisa B.E. Shields
  • Jonathan N. Howe
  • Todd S. Shanks
  • Aaron C. Spalding
چکیده

Occipital neuralgia generally responds to medical or invasive procedures. Repeated invasive procedures generate increasing complications and are often contraindicated. Stereotactic radiosurgery (SRS) has not been reported as a treatment option largely due to the extracranial nature of the target as opposed to the similar, more established trigeminal neuralgia. A dedicated phantom study was conducted to determine the optimum imaging studies, fusion matrices, and treatment planning parameters to target the C2 dorsal root ganglion which forms the occipital nerve. The conditions created from the phantom were applied to a patient with medically and surgically refractory occipital neuralgia. A dose of 80 Gy in one fraction was prescribed to the C2 occipital dorsal root ganglion. The phantom study resulted in a treatment achieved with an average translational magnitude of correction of 1.35 mm with an acceptable tolerance of 0.5 mm and an average rotational magnitude of correction of 0.4° with an acceptable tolerance of 1.0°. For the patient, the spinal cord was 12.0 mm at its closest distance to the isocenter and received a maximum dose of 3.36 Gy, a dose to 0.35 cc of 1.84 Gy, and a dose to 1.2 cc of 0.79 Gy. The brain maximum dose was 2.20 Gy. Treatment time was 59 min for 18, 323 MUs. Imaging was performed prior to each arc delivery resulting in 21 imaging sessions. The average deviation magnitude requiring a positional or rotational correction was 0.96 ± 0.25 mm, 0.8 ± 0.41°, whereas the average deviation magnitude deemed within tolerance was 0.41 ± 0.12 mm, 0.57 ± 0.28°. Dedicated quality assurance of the treatment planning and delivery is necessary for safe and accurate SRS to the cervical spine dorsal root ganglion. With additional prospective study, linear accelerator-based frameless radiosurgery can provide an accurate, noninvasive alternative for treating occipital neuralgia where an invasive procedure is contraindicated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CyberKnife in the treatment of prostate cancer: a revolutionary system.

The CyberKnife is a frameless advanced robotic system that uses image-guided radiotherapy (IGRT) and adaptive radiotherapy (ART) for stereotactic radiosurgery technique in intraand extracranial lesions. The CyberKnife has also revolutionised the use of radiosurgery to treat tumours in different parts of the body. This system represents, after three-dimensional conformal radiotherapy (3DCRT), a ...

متن کامل

Truebeam Radiosurgery for the Treatment of Trigeminal Neuralgia: Preliminary Results at a Single Institution

INTRODUCTION Radiosurgery is now an established method of satisfactory pain control in patients with trigeminal neuralgia (TN). The Varian Truebeam STx (Varian Medical Systems, Palo Alto, CA) linear accelerator (LINAC) system is an arc-based, frameless stereotactic radiosurgery system used for the treatment of TN. To our knowledge, there has been only one published series of patient histories t...

متن کامل

Stereotactic Radiosurgery and Stereotactic Body Radiotherapy

Patient Selection Criteria Coverage for the use of stereotactic radiosurgery (SRS) using a gamma or linear-accelerator (LINAC) will be considered when any of the following criteria are met:  Arteriovenous malformations;  Acoustic neuromas;  Pituitary adenomas;  Non-resectable, residual or recurrent meningiomas;  Craniopharyngiomas;  Glomus jugulare tumors;  Solitary or multiple brain met...

متن کامل

Radiosurgery for trigeminal neuralgia using a linear accelerator with BrainLab system: report on initial experience in Lausanne, Switzerland.

BACKGROUND/AIMS Radiosurgery is an effective treatment for trigeminal neuralgia (TN) with minimal complications. Most experience is based on gamma knife radiosurgery (GKRS) and to a lesser extent on linear accelerators. METHODS We report our initial experience in 17 patients with TN treated by an adapted linear accelerator using the BrainLab system. The trigeminal root entry zone immediately ...

متن کامل

The spatial accuracy of two frameless, linear accelerator‐based systems for single‐isocenter, multitarget cranial radiosurgery

Single-isocenter, multitarget cranial stereotactic radiosurgery (SRS) is more efficient than using an isocenter for each target, but spatial positioning uncertainties can be magnified at locations away from the isocenter. This study reports on the spatial accuracy of two frameless, linac-based SRS systems for multitarget, single-isocenter SRS as a function of distance from the isocenter. One sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017