Catheterization of pulmonary artery in rats with an ultraminiature catheter pressure transducer.

نویسندگان

  • Alexander Deten
  • Huntly Millar
  • Heinz-Gerd Zimmer
چکیده

Utilizing new materials and miniaturization techniques, an ultraminiature catheter pressure transducer for catheterization of the pulmonary artery (PA) has been developed and applied in intact, spontaneously breathing, anesthetized rats. The catheter arrangement consists of three components: 1) an SPR-671 ultraminiature pressure transducer (measuring catheter), 2) a plastic introducer (sheath) that is slipped over the measuring catheter, and 3) an external wire mounted on the outside of the introducer for bending its tip. The measuring catheter is first inserted through the right jugular vein into the right ventricle. The introducer is then slipped over it. The tip of the introducer is bent so that there is an angle of approximately 90 degrees or less to the shaft. The measuring catheter is advanced across the pulmonary valve into the PA. Measurements of pulmonary arterial pressure were made in five male Long Evans (364 +/- 7 g body wt) and five female Sprague-Dawley (244 +/- 7 g body wt) rats under control conditions. The effects of infusion of norepinephrine (0.1 mg.kg(-1).h(-1) iv for 20-min duration) were tested in Long Evans rats. Pulmonary arterial systolic pressure measurements were 34.0 +/- 0.8 and 29.5 +/- 0.4 mmHg, and diastolic pressure values were 23.6 +/- 0.8 and 18.1 +/- 0.6 mmHg in male Long Evans and female Sprague-Dawley rats, respectively. Norepinephrine induced an increase in pulmonary arterial systolic (40.8 +/- 0.1 mmHg) and diastolic (28.6 +/- 0.4 mmHg) pressures and an elevation in pulmonary vascular resistance from a control value of 0.093 +/- 0.003 to 0.103 +/- 0.004 mmHg.kg.min.ml(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه گیری فشار شریان ریوی توسط داپلر و مقایسه آن با روش کاتتریسم

Pulmonary artery pressure can be estimated from right ventricular-right atrial pressure gradient in patients with tricuspid regurgitation. The most common approach is to estimate pulmonary artery systolic pressure from right ventricular pressure (assuming no pulmonic stenosis) determined as the sum of the right ventricular-right atrial pressure gradient and either an assumed or clinically deter...

متن کامل

The design and implementation of a pulmonary artery catheterization simulator.

Pulmonary Artery Catheterization (PAC) is a commonly performed procedure. It is used when hemodynamic and other cardiac measures must be accurately monitored in seriously ill patients. A flow-directed, balloon-tipped (Swan-Ganz) catheter is typically inserted into a major vein, passed through the heart, and into the pulmonary artery. This procedure is normally not performed under fluoroscopy. I...

متن کامل

Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report

BACKGROUND Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct th...

متن کامل

Continuous ambulatory pulmonary artery pressure monitoring. A new method using a transducer tipped catheter and a simple recording system.

A transducer tipped catheter and simple recording system were used for the continuous measurement of ambulatory pulmonary artery pressure. The pulmonary artery pressure was recorded on a miniaturised tape recorder and replayed via an optical writer. Pulmonary arterial systolic and diastolic pressures can be analysed on a beat to beat basis. Continuous ambulatory monitoring was performed for a t...

متن کامل

False-positive diagnosis of pulmonary hypertension by Doppler echocardiography.

A 37-yr-old female presented with a history of several months of exertional dyspnoea. A diagnosis of primary pulmonary hypertension was suspected on the basis of a negative extensive cardiorespiratory work-up with a systolic pulmonary artery pressure of 41-46 mmHg calculated from repeated measurement of the maximum velocity of tricuspid regurgitation jets at 2.8-3 m x s(-1) by continuous-wave D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 285 5  شماره 

صفحات  -

تاریخ انتشار 2003