A comparison of 2-lead, 6-lead, and 12-lead ECGs in patients with changing edematous states: implications for the employment of quantitative electrocardiography in research and clinical applications.

نویسنده

  • John E Madias
چکیده

OBJECTIVE Precordial ECGs reveal significant intrasubject variability due to the inexact employment of the recommended V(1)-V(6) chest landmarks. Also, as per the Einthoven law, the six limb leads can be derived from leads 1 and 2. The purpose of this study was to evaluate whether the 12-lead ECG could be substituted by ECG sets with a limited number of leads. MATERIALS AND METHODS The performance of three ECG systems (ie, the 12-lead ECG, a 6-lead ECG comprising the limb leads, and a 2-lead ECG comprising exclusively leads 1 and 2) was evaluated in data from 28 patients with anasarca (AN), 28 control patients, 10 patients who had undergone hemodialysis, and 3 patients with idiopathic dilated cardiomyopathy. RESULTS Linear regression analyses of changes in ECG data with the weight gain of patients with AN and the intercorrelations of the three ECG systems in the various patient subgroups were found to be statistically significant at p = 0.0005 and r values ranging from 0.61 to 0.99, which are suggestive of good/excellent correlations. However, regression analyses of peak weight (PW) gain with changes in the 2-lead ECG (r = 0.43; p = 0.02) and 6-lead ECG (r = 0.48; p = 0.01), and half of PW gain and 12-lead ECG (r = 0.41; p = 0.03), 6-lead ECG (r= 0.18; p = 0.35), and 2-lead ECG (r = 0.43; p = 0.02) revealed poor correlations. CONCLUSION ECG systems, comprising 2 or 6 leads, can be substituted for the 12-lead ECG for certain clinical and research applications (pertaining to the amplitude of QRS complexes), attesting to the inherent redundancy of the information from the 12-lead ECG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T-wave inversion in the aVL lead is associated with severity of stenosis in the LAD artery

Background & Aims: The clinical value of T wave inversion (TWI) in the lead aVL in diagnosing coronary artery disease (CAD) remains unclear. Hence, we aim to evaluate the association between TWI in the aVL lead and the severity and location of coronary artery stenosis in elective coronary angiography. Material and Method: Electrocardiograms (ECGs) of 167 consecutive patients undergoing electiv...

متن کامل

Review and Performance Comparison of Lead-Free Shields and Lead Shields, In Terms of Biological Effects in Nuclear Medicine by the Comet Method

Introduction: Ionizing radiation can cause damage to biologically important DNA molecules. Radiation in nuclear medicine radiation exposes people working in from two main positions; administer in gradiopharmaceuticals (the barn and squeezing a generator, procurement, distribution and drug infusion) and patients that receive radiation treatment (patients that are prescribed a ra...

متن کامل

Influence of lead selection and population on automated measurement of QT dispersion.

BACKGROUND The study of QT dispersion (QTd) is of increasing clinical interest, but there are very few data in large healthy populations. Furthermore, there is still discussion on the extent to which QTd reflects dispersion of measurement. This study addresses these problems. METHODS AND RESULTS Twelve-lead ECGs recorded on 1501 apparently healthy adults and 1784 healthy neonates, infants, an...

متن کامل

Comparison between Clinically Used Irregular Fields Shielded by Cerrobend and Standard Lead Blocks

Introduction: In radiation therapy centers across Iran, protection of normal tissues is usually accomplished by either Cerrobend or lead block shielding. In this study, the influence of these two shielding methods on central axis dose distribution of photon beam a Cobalt unit was investigated in clinical conditions. Materials and Methods: All measurements were performed for 60Co γ-ray beams an...

متن کامل

Electrocardiographic parameters of Markhoz goat using base apex lead and six standard limb leads

Electrocardiographic study of 50 healthy Markhoz goats ranging from less than 1 to more than 3 years inage was carried out. The heart rate varied from 99 to 123 beats/min with a mean of 110 beats/min. There wasa significant difference between the heart rate of goats in 3 age groups (PT waves and QT interval in base apex lead, QRS wave in lead I, P-R and PQ interval in aVF lead were higherand du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 124 6  شماره 

صفحات  -

تاریخ انتشار 2003