Determination of phenylephrine hydrochloride by flow injection analysis with chemiluminescence detection.

نویسندگان

  • Y F Mestre
  • L L Zamora
  • J M Calatayud
چکیده

A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80 degrees C. The calibration graph is linear over the range 0.03-8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ppm) of 1.1% and sample throughput of 134/h. The influence of 38 different foreign compounds was tested, and the method was applied to the determination of phenylephrine hydrochloride in 8 different pharmaceutical formulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric determination of phenylephrine hydrochloride in pharmaceuticals by flow injection analysis exploiting the reaction with potassium ferricyanide and 4-aminoantipyrine.

This paper presents a method for the determination of phenylephrine hydrochloride in pharmaceuticals by spectrophotometric flow injection analysis exploiting the reaction with potassium ferricyanide and 4-aminoantipyrine, which leads to the formation of a condensation product with strong absorptivity at 500 nm. The linear dynamic range was between 0.95 and 9 mg/L, with a limit of detection of 0...

متن کامل

Flow Injection Determination of Tramadol Based on Its Sensitizing Effect on the Chemiluminescent Reaction of Permanganate-Sulfite

In this paper, a novel chemiluminescence (CL) method for the determination of tramadol has been developed by combining the flow injection technique and its sensitizing effect on the weak CL reaction between sulfite and acidic KMnO4. A mechanism for the CL reaction has been proposed on the basis of fluorescent and CL spectra. Under the optimized conditions, the proposed method allows the measure...

متن کامل

Flow-injection chemiluminometric analysis of some benzamides by their sensitizing effect on the cerium-sulphite reaction.

A simple, highly sensitive chemiluminescent method using flow injection is described for the determination of three substituted benzamides, namely: sulpiride, sultopride and tiapride. The method is based on the sensitizing effect of these drugs on the chemiluminometric oxidation of sulphite by cerium(IV). The different experimental parameters affecting the chemiluminescence intensity were caref...

متن کامل

Determination of phenolic sympathomimetic drugs in pharmaceutical samples and biological fluids by flow-injection chemiluminescence.

A rapid and highly sensitive flow-injection chemiluminometric method was developed for determination of 3 sympathomimetic drugs, namely, etilefrine hydrochloride, isoxsuprine hydrochloride, and prenalterol hydrochloride. The method is based on chemiluminescence induced by oxidation of drugs with acidified potassium permanganate in the presence of formic acid as a carrier. The calibration graphs...

متن کامل

An overview on flow methods for the chemiluminescence determination of phosphorus.

A review on the flow analysis of phosphorus with chemiluminescence detection is presented. A brief discussion of the chemiluminescence principles and applications is given. Particular emphasis is devoted to coupling different flow techniques (flow injection, sequential injection, multicommutation, multisyringe flow injection, multi-pumping) to chemiluminescence detection. Enzymatic and non-enzy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 1  شماره 

صفحات  -

تاریخ انتشار 2001