Embolic protection with filtering or occlusion balloons during saphenous vein graft stenting retrieves identical volumes and sizes of particulate debris.

نویسندگان

  • Campbell Rogers
  • Rany Huynh
  • Philip A Seifert
  • Bernard Chevalier
  • Joachim Schofer
  • Elazer R Edelman
  • Gregory Toegel
  • Arun Kuchela
  • Amy Woupio
  • Richard E Kuntz
  • Natalie D Macon
چکیده

BACKGROUND Distal embolization of plaque particulate liberated during stenting may cause periprocedural complications. The number, size, and volume of debris released during stenting, however, have not been quantified, rendering embolic protection approaches empiric. We used a novel method of microparticle size assessment to measure volume and characterize individual sizes of particles captured by the PercuSurge GuardWire balloon or a vascular filter during saphenous vein graft stenting. METHODS AND RESULTS Braided nitinol filters (average distal pore size 100 microns) were used in 47 saphenous vein grafts in 44 patients. The PercuSurge GuardWire was used in 17 saphenous vein grafts in 16 patients. Particulate debris was subjected to microparticle size analysis (RapidVue, Beckman Coulter). All samples contained particulate debris. For both filter and GuardWire populations, most particles were <100 microm in longest dimension (87% and 90% of particles, respectively), and the distribution of particle sizes was identical. Total embolic load per lesion for both filters and GuardWire aspirates was also similar: median embolic load per filter was 16 mm3 (range 2 to 84 mm3). Median embolic load per GuardWire was also 16 mm3 (range 7 to 42 mm3). Histopathologic analysis demonstrated that most samples contained plaque elements and platelet-rich thrombus. CONCLUSIONS During saphenous vein graft interventions, particulate retrieved with a vascular filtering device or an occlusion balloon was similar in amount and character. This supports the notion that unless soluble mediators play an important role in adverse acute clinical events after stenting, the clinical efficacy of filtering devices may be equal to that of occlusion devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adjuvant therapy of breast cancer in the elderly: does one size fit all?

6. de Feyter PJ. Percutaneous treatment of saphenous vein bypass graft obstructions: a continuing obstinate problem. 7. Bejarano J. Mechanical protection of cardiac microcirculation during percuta-neous coronary interevntion of saphenous vein grafts. Int J Cardiol. In press. 8. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervent...

متن کامل

An update on herpes virus infections in graft recipients.

percutaneous coronary and carotid interventions. Curr Control Trials Cardiovasc Med 2001; 2: 286–291 11. Angelini A, Reimers B et al. Cerebral protection during carotid artery stenting. Stroke 2002; 33: 456–461 12. Webb JG, Carere RGC, Virmani R et al. Retrieval and analysis of particulate debris after saphenous vein graft intervention. J Am Col Cardiol 1999; 34: 468–475 13. Baim DS, Wahr D, Ge...

متن کامل

Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.

BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...

متن کامل

Retrieval and analysis of particulate debris after saphenous vein graft intervention.

OBJECTIVES This study was designed to evaluate the composition and quantity of particulate debris resulting from vein graft intervention. BACKGROUND Distal embolization and "no reflow" are frequent and important complications resulting from angioplasty of diseased saphenous vein grafts. Little is known about the composition and quantity of embolic particulate debris associated with vein graft...

متن کامل

Embolic protection devices.

M anipulation of atherosclerotic lesions with wires, cath-eters, balloons, stents, and other intravascular devices during invasive procedures releases atherosclerotic plaque, resulting in distal embolization. This plaque debris leads to no or slow flow as a result of a multitude of factors, including mechanical obstruction of macrovascular and microvascu-lar channels, local platelet adhesion, p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 109 14  شماره 

صفحات  -

تاریخ انتشار 2004