Analysis of the Time and Location of the Silicone Oil Emulsification by Spectral-Domain Optical Coherence Tomography after Silicone Oil Tamponade

نویسندگان

  • Dominik Odrobina
  • Iwona Laudańska-Olszewska
چکیده

PURPOSE To estimate localization and the period up to the appearance of small hyperreflective round-shaped droplets using spectral-domain optical coherence tomography (SD-OCT) after pars plana vitrectomy with silicone oil tamponade. METHODS A retrospective observational study included 24 patients who had undergone pars plana vitrectomy with silicone oil tamponade for proliferative vitreoretinopathy (PVR) retinal detachment. SD-OCT analysis was performed 1, 3, and 6 months after surgery. We characterized the emulsified silicone oil in the SD-OCT as the small hyperreflective round-shaped droplets. RESULTS In SD-OCT examination, none of the patients had hyperreflective round-shaped droplets visible one month after vitrectomy with silicone oil tamponade. The hyperreflective droplets were found three months after surgery-in one patient above the optic nerve and in five patients intraretinally (in the cystoid spaces). Six months after vitrectomy, the hyperreflective round-shaped droplets were still present in the aforementioned patients' eyes and additionally in 3 eyes above the optic disc. CONCLUSIONS Hyperreflective round-shaped droplets were found in a SD-OCT examination 3 months after silicone oil tamponade. The authors suggest that they are most likely the emulsified silicone oil droplets. The authors hypothesize that emulsification and migration of silicone oil begin within 3 months after surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal layers measurements in healthy eyes and in eyes receiving silicone oil-based endotamponade

PURPOSE To characterize the concordance/symmetry of each retinal layers in individuals without macular pathology and to further characterize the localization of inner retinal thinning in eyes receiving silicone oil-based endotamponade. METHODS Retinal layers of one hundred eyes of 50 individuals without macular pathology were imaged using spectral domain optical coherence tomography (SD-OCT) ...

متن کامل

Full Thickness Macular Hole Closure after Exchanging Silicone-Oil Tamponade with C3F8 without Posturing

PURPOSE To report a case of macular hole closure after the exchange of a silicone-oil tamponade with gas C(3)F(8) 14%. METHOD A 64-year-old female patient with a stage IV macular hole underwent a three-port pars-plana vitrectomy and internal limiting membrane peeling. Due to the patient's chronic illness (respiratory problems), a silicone-oil tamponade was preferred. However, the macula hole ...

متن کامل

Vision loss associated with the use and removal of intraocular silicone oil

PURPOSE To describe vision loss associated with the use or removal of silicone oil retinal tamponade. METHODS Records were reviewed of all patients with a decrease in visual acuity of at least 3 Snellen lines from best acuity with 5000 centistoke silicone oil in place or after removal of silicone oil at a single retina-only practice between 1996 and 2006. RESULTS Nine patients (6 men, 3 wom...

متن کامل

The effect of vitrectomy with silicone oil tamponade on intraocular pressure and anterior chamber morphology.

We measured the tamponading effect of silicone oil, saline and air after vitrectomy, on intraocular pressure and aqueous humor outflow in 85 patients with highly proliferative retina and vitreous changes. Silicone oil as retinal tamponading agent after vitrectomy was used in 45 patients, and saline or air in 39 patients. The mean intraocular pressure measured at one month after treatment was gr...

متن کامل

Outer Retinal Changes on Spectral-Domain Optical Coherence Tomography Pre- and Post-Silicone Oil Removal.

BACKGROUND AND OBJECTIVE To evaluate outer retinal changes present on spectral-domain optical coherence tomography (SD-OCT) in eyes pre- and post-silicone oil (SiO) removal (SOR). PATIENTS AND METHODS Retrospective case series of patients who underwent pars plana vitrectomy with SiO instillation and had SD-OCT completed pre- and post-SOR. SD-OCT parameters included presence of subretinal flui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014