Bispectral index and other processed parameters of electroencephalogram: an update.

نویسندگان

  • Rogean Rodrigues Nunes
  • Itagyba Martins Miranda Chaves
  • Júlio César Garcia de Alencar
  • Suyane Benevides Franco
  • Yohana Gurgel Barbosa Reis de Oliveira
  • David Guabiraba Abitbol de Menezes
چکیده

BACKGROUND AND OBJECTIVES The processed analysis of electroencephalogram became extremely important to monitor nervous system, being used to obtain a better anesthetic adequacy. The objective was to conduct a review about each processed parameter, defining its real importance. CONTENT A review was conducted showing mathematical, physical and clinical aspects as well as their correlations and updates, presenting new integrated parameters. CONCLUSIONS An adequate analysis of processed parameters of electroencephalogram may provide more intraoperative safety as well as result in a better outcome for the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bispectral index decreased to "0" in propofol anesthesia after a cross-clamping of descending thoracic aorta.

THE Bispectral Index (BIS) monitor (BIS® monitor; Aspect Medical System, Inc., Newton, MA) integrates electroencephalographic data via a proprietary algorithm based on empirical data into a nominal 100 to 0 scale, in which 100 represents the awake state and 0 represents the isoelectric electroencephalogram. The BIS® monitor is highly capable of correctly predicting both the loss and recovery of...

متن کامل

Estimation of the bispectral index by anesthesiologists: an inverse turing test.

BACKGROUND Processed electroencephalographic indices, such as the bispectral index (BIS), are potential adjuncts for assessing anesthetic depth. While BIS® monitors might aid anesthetic management, unprocessed or nonproprietary electroencephalographic data may be a rich source of information for clinicians. We hypothesized that anesthesiologists, after training in electroencephalography interpr...

متن کامل

Bispectral index profile during carotid cross clamping.

This study aimed at investigating the Bispectral Index (BIS) profile during carotid cross clamping (CXC). The study involved a pilot group of 10 patients undergoing routine carotid endarterectomy with shunt insertion under total intravenous anesthesia, and a study group of 26 additional patients. In all patients, rates of propofol and remifentanil providing a steady-state level of hypnosis (BIS...

متن کامل

Monitoring depth of anesthesia utilizing a combination of electroencephalographic and standard measures.

BACKGROUND For decades, monitoring depth of anesthesia was mainly based on unspecific effects of anesthetics, for example, blood pressure, heart rate, or drug concentrations. Today, electroencephalogram-based monitors promise a more specific assessment of the brain function. To date, most approaches were focused on a "head-to-head" comparison of either electroencephalogram- or standard paramete...

متن کامل

Monitoring the anaesthetic depth in children - an update.

PURPOSE OF REVIEW There are several commercially available electroencephalogram-derived devices for monitoring anaesthesia depth. This article reviews all published studies describing their use in children; first assessing studies of performance in measuring anaesthesia depth in observational, physiological studies and then describing relevant outcome studies. There is also a brief discussion o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de anestesiologia

دوره 62 1  شماره 

صفحات  -

تاریخ انتشار 2012