The Role of the Three Phase Bone Scintigraphy in the Management of the Patients with Costochondral Pain

نویسندگان

  • Zehra Pınar Koç
  • Tansel Ansal Balcı
  • M. Oğuzhan Özyurtkan
چکیده

AIM The bone scintigraphy is indicated in patients with costochondral pain in order to identify the organic etiology. We aimed to investigate the local and projecting pain, or incidental findings in the three phase bone scintigraphy of the patients referred for costochondral pain. METHODS We included 50 patients (36F, 24M; mean: 41±18 years-old) referred to our department for three phase bone scintigraphy for costochondral pain between January 2009-July 2012. RESULTS Among the 50 patients 22 had normal scintigraphy. An increased activity accumulation in the sternoclavicular joint was observed in 12 patients (right in 4, left in 4 and bilateral in 4) only in late phase and in 9 patients (right in 2, left in 1 and bilateral in 6) with increased vascularity. Among projecting pain causes, activity was present on sternum in 4 patients, on humerus in 2 patients and on the first costae in 2 patients. For the characterization of inflammatory pathology, the three phase bone scintigraphy showed sensitivity, specificity, accuracy, positive and negative predictive values of 43%, 94%, 78%, 77% and 78% respectively. CONCLUSION Bone scintigraphy is an effective diagnostic method for the identification of local or projecting pain, and additionally unexpected incidental pathologies ssociated with costochondral pain. However regarding the characterization of inflammatory process false negatives should be considered. CONFLICT OF INTEREST None declared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Additive clinical value of bone scintigraphy in patients with malignant tumors with absence of localized bone pain: A report on most common sex-related cancers

  Introduction: Almost all malignant tumors have the potential to eventually produce bone metastasis. The aim of the current study was to report the distribution pattern and imaging characteristics of bone metastases detected by conventional whole body bone scintigraphy in patients with different types of malignancies and to assess their relationship with the complain...

متن کامل

Can three-phase skeletal scintigraphy predict the outcome and determine the timing of removal of bone distracters in avascular necrosis of femur using a novel corticostomy technique?

Introduction: 99mTc-Methylene diphosphonate (99mTc-MDP) three phase bone scintigraphy (TPS) is beneficial to evaluate the success of femoral head revascularization using novel distraction osteogenesis techniques with bone muscle pedicle grafts. This pilot study was undertaken to evaluate the feasibility and utility of 99mTc-MDP three phase bone ...

متن کامل

Usefulness of three-phase bone scintigraphy and SPECT/CT for the diagnosis of bone lesions of systemic sarcoidosis

We report a three-phase bone scintigraphy for the diagnosis of a peripheral bone lesion caused by systemic sarcoidosis. A 32-year-old man with suspected osteomyelitis of the right forefinger underwent three-phase bone scintigraphy with Tc-99m hydroxymethylene diphosphonate (HMDP) and single-photon emission computed tomography/computed tomography (SPECT/CT). The lesion was rich in blood flow acc...

متن کامل

99mTc-MIBI scintigraphy in musculoskeletal tumors [Persian]

The aim of this study was to assess the value of 99mTc-hexakis-2-methoxyisobutylisonitrile (MIBI) scintigraphy in patients with clinical and radiologic features of primary or metastatic musculoskeletal tumors. Methods: The scintigraphic findings for 84 patients were compared with the surgical and histologic findings. Each patient underwent three-phase bone scan with 99mTc-methylene diphos...

متن کامل

Dichotomous Indium-111 labeled leukocyte scan findings while evaluating osteomyelitis in a failed mandibular graft

Markedly elevated111 In labeled leukocyte activity suggestive of acute osteomyelitis was observed in a region of a composite mandibular allograft that was photon deficient on 99mTc MDP bone scintigraphy. This finding was later confirmed by surgical pathology. The patient was treated with intravenous antibiotics and returned two months later with persistent bone infection. The foHow-up thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2013