Fluidics in a dual pneumatic ultra high-speed vitreous cutter system.
نویسندگان
چکیده
BACKGROUND Dual pneumatic systems use two separate air line tubes to open and close the cutter and can achieve high cut rates. The purpose of this study is to evaluate the influence of gauge size, cut rate and aspiration on the flow rate performance of ultra high-speed cutters operated with a commercially available dual pneumatic vitrectomy system. METHODS Analysis of a high-speed video was used to determine duty cycle. Flow rates from 20-, 23- and 25-gauge cutters were calculated in predetermined conditions of aspiration levels and cut rates; water and fresh porcine vitreous samples were studied. RESULTS For all three gauges of cutters, the duty cycle and water flow showed an inverse correlation with increasing cut rates and a direct correlation with increasing aspiration levels (p < 0.05). Vitreous flow rates from all gauges increased with increasing aspiration and cut rates (p < 0.05). CONCLUSION Larger gauges of the cutters as well as higher aspiration and cut rate levels resulted in improvement of the vitreous flow rates. A good understanding of the different flow rate settings is essential for the surgeon and optimizes the safety of surgical procedures.
منابع مشابه
Vitreous flow rates through dual pneumatic cutters: effects of duty cycle and cut rate
PURPOSE We aimed to investigate effects of instrument settings on porcine vitreous flow rates through dual pneumatic high-speed vitrectomy probes. METHODS The CONSTELLATION(®) Vision System was tested with 250, 450, and 650 mmHg of vacuum using six ULTRAVIT(®) vitrectomy probes of each diameter (25+(®), 25, 23, and 20 gauge) operated from 500 cuts per minute (cpm) up to 5,000 cpm. Duty cycle ...
متن کاملPorcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute
PURPOSE To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27+-, 25+-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by La...
متن کاملTreatment of Dropped Nucleus with a 27-Gauge Twin Duty Cycle Vitreous Cutter
We report herein a method for the treatment of dropped nucleus during cataract surgery with a 27-gauge twin duty cycle (TDC) vitreous cutter. When a TDC vitreous cutter is used, suction flow volume is maintained even when the cutter is driven at a high speed. This enables an Emery-Little grade 3 nucleus that had been difficult to treat with a conventional 27-gauge cutter to be successfully exci...
متن کاملDesign and Manufacture of a Smart Orthopedic Pin Cutter for Use in the Operating Room and Patients Undergoing Orthopedic Surgery
Background and Aim: Since pin cutter is used in surgical operations involving screw and orthopedic plating and this is one of the most sensitive surgeries, saving time is very important along with reducing infection rate. The purpose of design the Mini-Pin Cutter is to replace a smaller, lighter, more efficient device than conventional and traditional cutters, which ultimately results in a comf...
متن کاملIntroducing new vitreous cutter blade shapes: a fluid dynamics study.
PURPOSE To assess the efficacy of novel vitreous cutter blades compared with the regular guillotine by means of particle image velocimetry. Tested blades included a regular blade (RB) and newer designs where a circular (hole blade [HB]) or a slit aperture (slit blade [SB]) had been opened proximal to the cutting edge. METHODS Twenty-three-gauge probes were immersed in BSS or egg albumen, and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde
دوره 229 1 شماره
صفحات -
تاریخ انتشار 2013