Pulse oximetry as a potential screening tool for lower extremity arterial disease in asymptomatic patients with diabetes mellitus.
نویسندگان
چکیده
BACKGROUND Lower extremity arterial disease (LEAD) is common and underdiagnosed in patients with diabetes mellitus and is associated with higher total mortality. METHODS We compared the accuracy of pulse oximetry, the ankle-brachial index (ABI), and the combination of the two to diagnose LEAD in consecutive outpatients with type 2 diabetes who had no symptoms of LEAD, in a primary care setting. Exclusions were age younger than 40 years, known LEAD, or typical symptoms of LEAD. Fifty-seven patients were enrolled. All patients had (1) ABI measurement; (2) pulse oximetry to measure Sao2 of their index fingers and big toes in the supine position and at 12-in elevation; and (3) Doppler waveform analysis of the lower extremity arteries. The ABI was considered abnormal if it was less than 0.9. Pulse oximetry of the toes was considered abnormal if the Sao2 was more than 2% lower from the finger or on 12-in elevation of the foot. The combination was considered positive if either the ABI or pulse oximetry was positive for LEAD and negative if both were negative. We defined LEAD as monophasic waveforms on waveform analysis. RESULTS Of our patients, 31% had LEAD. Pulse oximetry had a sensitivity of 77% (95% confidence interval [CI], 61%-88%) and a specificity of 97% (95% CI, 91%-99%); ABI had a sensitivity of 63% (95% CI, 46%-77%) and a specificity of 97% (95% CI, 91%-99%). Positive likelihood ratios were 30 (95% CI, 7.6-121) for pulse oximetry and 24.8 (95% CI, 6.2-99.8) for ABI; negative likelihood ratios were 0.23 (95% CI, 0.12-0.43) for pulse oximetry and 0.38 (95% CI, 0.25-0.59) for ABI. For the combination, sensitivity was 86% (95% CI, 71%-94%) and specificity was 92% (95% CI, 84%-96%). CONCLUSIONS Pulse oximetry of the toes seems as accurate as ABI to screen for LEAD in patients with type 2 diabetes. Combination of the two tests increases sensitivity.
منابع مشابه
Utility of digital pulse oximetry in the screening of lower extremity arterial disease
PURPOSE The aim of this study was to evaluate screening methods in the lower extremities by measurement of the digital pulse oximetry (oxygen percent saturation [SpO(2)]) of toes for peripheral arterial disease (PAD). METHODS A prospective study was performed among 49 patients (98 limbs) with lower extremity arterial occlusive disease. We attempted to measure the ankle-brachial index (ABI), d...
متن کاملComparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life
Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...
متن کاملSensitivity and Specificity of Pulse Oximetry and Ankle-Brachial Index for Screening Asymptomatic Peripheral Vascular Diseases in Type 2 Diabetes Mellitus.
OBJECTIVES To compare pulse oximetry and Ankle-Brachial Index (ABI) with duplex ultrasonography as reference standard to determine the diagnostic accuracy for screening asymptomatic PVD in type 2 diabetes mellitus. METHODS This cross-sectional study was conducted in 2012 at tertiary hospital in Madurai among diabetic patients attending the medicine outpatient department (OPD). Type 2 Diabetes...
متن کاملEvaluation of Pulse Oximetry in the Early Diagnosis of Cardiac and NonCardiac Diseases in Healthy Newborns
Background: Critical congenital heart diseases (CCHDs) are among the most common birth malformations. This study aimed to determine the cardiac and noncardiac diseases in the Iranian healthy newborns using pulse oximetry (POX) as a suggested screening method.Methods: In this cross-sectional study, healthy term and near term neonates who were born from October 2017 to March 2018 were evalu...
متن کاملPulse pressure and Michigan Neuropathy Screening Instrument are independently associated with asymptomatic peripheral arterial disease among type 2 diabetes community residents: a community-based screening program in Taiwan.
BACKGROUND Peripheral arterial disease (PAD) is one of the major manifestations of systemic atherosclerosis and plays an important role in low-extremity amputation in type 2 diabetic patients. The aim of this study was to explore the prevalence and risk factors for asymptomatic PAD in type 2 diabetic community residents. METHODS This cross-sectional study enrolled 552 type 2 diabetic adults (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of internal medicine
دوره 165 4 شماره
صفحات -
تاریخ انتشار 2005