Absolute determination method using chirality for glufosinate and bialaphos by gamma-cyclodextrin modified capillary zone electrophoresis.

نویسندگان

  • Takayuki Asami
  • Hisanori Imura
  • Akira Ohashi
  • Kousaburo Ohashi
  • Tetsuya Ishiwata
چکیده

A novel absolute determination method using chirality without any calibration curves or comparison standards has been proposed for phosphorus-containing amino acid-type herbicides, glufosinate (D,L-GLUF) and bialaphos (BIAL). This method is based on a change in the enantiomeric ratio after the spiking of a known amount of the enantiomers with different enantiomeric ratios to a sample. D,L-GLUF was determined by adding a known amount of L-GLUF to the sample, derivatizing them with dansyl chloride, and measuring the ratio of the peak area of the D-isomer to that of the L-isomer by means of gamma-cyclodextrin modified capillary zone electrophoresis. The accuracy and precision of the method were evaluated using a synthetic sample. The mean values obtained for D- and L-GLUF agreed with the values taken within 1.6%; also the reproducibility was as good as less than 2.8%. The determination of BIAL was achieved by determining GLUF quantitatively produced by the acid hydrolysis of BIAL. The proposed methods were applied to the analysis of commercial herbicides and the validity and usefulness were evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of phosphorus-containing amino acid-type herbicides by sheathless capillary electrophoresis/electrospray ionization-mass spectrometry using a high sensitivity porous sprayer.

We describe a new practical capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) method for the forensic analysis of phosphorus-containing amino acid-type herbicides, glyphosate (GLYP), glufosinate (GLUF) and bialaphos (BIAL). A new sheathless interface, a high sensitivity porous sprayer (HSPS), was used in this study. The limits of detections of GLYP, GLUF and BIAL w...

متن کامل

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Application of Guanidine Hcl to Improve Enantioseparation of a Model Basic Drug, Cetirizine, By Capillary Electrophoresis Using Sulfated Β-Cyclodextrin

A common approach in resolving enantiomers of chiral basic drugs by capillary electrophoresis (CE) is to use cyclodextrins (especially their anionic derivatives) as chiral selector in the acidic buffer (pH ≤ 3) in normal or reversed (carrier) mode. Then, some organic modifiers are added to the buffer solution if the resolution is not satisfactory. In case of cetirizine (CTN), applying the same ...

متن کامل

Cyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis

Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...

متن کامل

Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis

Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2005