BACKGROUND A wide variety of complications due to the extrauterine migration of intrauterine contraceptive devices have been reported in the literature. Here we describe the case of a large bladder stone formed around a migrated Copper T380A device that was neglected and detected 15 years after insertion. CASE PRESENTATION A 48-year-old Sri Lankan woman underwent a workup for lower urinary tract symptoms and recurrent urinary tract infections over the previous 6 months. The radiographs showed a large bladder stone with an imprint of an intrauterine contraceptive device in the center of it. The device had been inserted 15 years previously. Two years after the insertion, it was considered to be missing, but our patient did not comply with the recommended follow-up. She had been completely asymptomatic until she developed lower urinary tract symptoms. After confirming the location of the stone via ultrasonography, a vesicolithotomy was performed, revealing a stone with three limbs corresponding to the shape of the Copper T380A device. The device and the threads were fully covered with the stone material. Our patient was asymptomatic following the surgery. CONCLUSIONS A migrated intrauterine contraceptive device can act as the nidus for the formation of a secondary bladder stone. The detailed imprint of the device inside the stone and the laminated appearance of the stone material were characteristic of a secondary bladder stone formed around an intrauterine contraceptive device. Radiography and ultrasonography are adequate for the diagnosis of intravesical migration of intrauterine contraceptive devices.
منابع مشابه
Vesical Calculus 10 Years Post Missing Intrauterine Contraceptive Device
Intravesical migration of intrauterine contraceptive device (IUCD) is rare. Early diagnosis of this rare entity is difficult because of its non-specific manifestations and very low index of suspicion. We present this case of bladder stone following intravesical migration of IUCD found to have been missing since insertion 10 years earlier. Lower abdominal discomfort and a missing vaginal string ...
متن کاملIntravesical Migration of Missed Intrauterine Device Associated with Stone Formation: A Case Report and Review of the Literature
Intrauterine device is the most widely used method of reversible contraception. It may cause various complications including perforation of uterus. In this case, 44-year-old woman was presented with lower urinary tract symptoms after six years of insertion. Patient has no remarkable physical or laboratory finding but abdominal ultrasound revealed a 27 mm hyperechogenicity, suggestive of foreign...
متن کاملIntravesical Migration of an Intrauterine Contraceptive Device with Secondary Calculus Formation
Intrauterine contraceptive devices (IUCDs) are a common form of reversible contraception owing to fewer systemic side effects and low cost, especially in a developing country like India. However, IUCDs are not without complications. Migration of a device into adjacent organs is the most morbid of all the documented complications. A patient who presents with a history that suggests loss or disap...
متن کاملEndoscopic Treatment of Intrauterine Device Migration into the Bladder with Stone Formation
Background: An intrauterine device is commonly used for contraception globally. Although intrauterine device placement is an effective and safe method of contraception, migration into the bladder with stone formation is a rare and serious complication. The management approaches for an intrauterine device embedded in the bladder include endoscopic procedures and open surgical removal. In this st...
متن کاملThe Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report
Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...