The influence of length of implant on primary stability: An in vitro study using resonance frequency analysis

نویسندگان

  • Anwar B. Bataineh
  • Ala M. Al-dakes
چکیده

BACKGROUND Primary stabilityis not sufficientin less contact area between the implant and bone, the healing process because will be disrupted due to micro-motions and fibrous tissue affects osseointegration. MATERIAL AND METHODS We implemented an in vitro experimental study of total 135 XiVE® implants were inserted in 22.5 bovine cow ribs with bone quality similar to a type IV human bone. Each rib end received a group of three different implant lengths, which were 8mm, 13mm and 15mm and had the same diameter 3.8mm. Immediately after the implant placement, its primary stability was measured using Osstell Mentor equipment. ANOVA Tukey's honest to test the significant difference were performed for data analysis between the resonance measures of the different lengths of implants. Statistical significance was assessed at a level P< 0.05. RESULTS A total of 45 implants were inserted for each length at cortical bone level. A significant difference between the three groups in favor of implant with 15mm length group (P = 0.000). CONCLUSIONS Increasing dental implant length is considered to play a fundamental role in increasing dental implant primary stability, even in poor bone quality, through controlling the bone preparation process. Key words:Dental implants, primary stability, resonance frequency analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Site Preparation (Countersinking) on Initial Dental Implant Stability. An in vitro Study Using Resonance Frequency Analysis

Primary implant stability is considered to be a critical factor for obtaining successful osseointegration [1]. Studies using Resonance Frequency Analysis (RFA) have demonstrated that initial implant stability is determined by the density of the bone, the surgical technique used, and the design of the implant [2, 3]. While different implant designs have shown similar results of higher stabilitie...

متن کامل

Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites

Background and aim:  Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...

متن کامل

Application of the method of multiple scales for nonlinear vibration analysis of mechanical systems with dry and lubricated clearance joints

In this study, the method of multiple scales is used to perform a nonlinear vibration analysis of a mechanical system in two cases; with dry and lubricated clearance joints. In the dry contact case, the Lankarani-Nikravesh model is used to represent the contact force between the joined bodies. The surface elasticity is modeled as a nonlinear spring-damper element. Primary resonance is discussed...

متن کامل

ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency

BACKGROUND Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be inve...

متن کامل

In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems.

AIMS Immediate loading has become a predictable option for treatment, while one of the main requirements for its implementation is obtaining appropriate primary stability in implants. With that aim, conical implants are commercially available, since, according to specialized literature, they provide greater stability. One of the methods to measure implant stability which has evolved to further ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017