Region of interest tomography of bigger than detector samples.

نویسندگان

  • B Schillinger
  • N Kardjilov
  • A Kuba
چکیده

For many neutron tomography setups, the maximum sample size for tomography is limited by a comparatively small beam cross section. However, it is not well known outside the medical field that it is possible to perform region-of-interest tomography of sections inside the object that fit into the beam and detector area. Approximately valid reconstruction data appear in a circle with a diameter of approximately the detector width, but with incomplete data and strong artifacts outside that circle. These artifacts can be removed either by mathematical means or by simple geometrical cutting of the reconstructed data, enabling the examination of samples bigger than the detector or beam area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

Optimization of Gate’s technique for measurement of GFR during routine renal scan [Persian]

Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2004