Forward planned intensity modulated radiotherapy (IMRT) for whole breast postoperative radiotherapy. Is it useful? When?

نویسندگان

  • Alessio G. Morganti
  • Savino Cilla
  • Andrea de Gaetano
  • Simona Panunzi
  • Cinzia Digesù
  • Gabriella Macchia
  • Mariangela Massaccesi
  • Francesco Deodato
  • Gabriella Ferrandina
  • Numa Cellini
  • Giovanni Scambia
  • Angelo Piermattei
  • Vincenzo Valentini
چکیده

The purpose was to compare the dosimetric results observed in 201 breast cancer patients submitted to tangential forward intensity-modulated radiation therapy (IMRT) with those observed in 131 patients treated with a standard wedged 3D technique for postoperative treatment of whole breast, according to breast size and supraclavicular node irradiation. Following dosimetric parameters were used for the comparison: D(max), D(min), D(mean), V(95%) and V(107%) for the irradiated volume; D(max), D(mean), V(80%) and V(95%) for the ipsilateral lung; D(max), D(mean), V(80%) and V(95%) for the heart. Stratification was made according to breast size and supraclavicular (SCV) nodal irradiation. As respect to irradiated volume, a significant reduction of V(107%) (mean values: 7.0 ± 6.6 versus 2.4 ± 3.7, p < 0.001) and D(max) (mean % values: 111.2 ± 2.7 versus 107.7 ± 6.3, p < 0.001), and an increase of D(min) (mean % values: 65.0 ± 17.4 versus 74.9 ± 12.9, p < 0.001) were observed with forward IMRT. The homogeneity of dose distribution to target volume significantly improved with forward IMRT in all patient groups, irrespective of breast size or supraclavicular nodal irradiation. When patients treated with supraclavicular nodal irradiation were excluded from the analysis, forward IMRT slightly reduced V(80%) (mean values: 3.7 ± 2.6 versus 3.0 ± 2.4, p = 0.03) and V(95%) (mean values 1.9 ± 1.8 versus 1.2%± 1.5; p = 0.001) of the ipsilateral lung. The dose to the heart tended to be lower with IMRT but this difference was not statistically significant. Tangential forward IMRT in postoperative treatment of whole breast improved dosimetric parameters in terms of homogeneity of dose distribution to the target in a large sample of patients, independent of breast size or supraclavicular nodal irradiation. Lung irradiation was slightly reduced in patients not undergoing to supraclavicular irradiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011