Dependence of the anti-CD66 antibody biodistribution on the dissociation constant: a simulation study.

نویسندگان

  • Peter Kletting
  • Sven N Reske
  • Gerhard Glatting
چکیده

In radioimmunotherapy (RIT) with radiolabelled anti-CD66 antibody, the red bone marrow is selectively irradiated. A preceding study, employing a physiologically based pharmacokinetic model, has shown that currently about 50% of the anti-CD66 antibody is accumulated in the red marrow. In this work, the potential improvement of the biodistribution is quantified for other anti-CD66 antibodies with lower dissociation constants K(D). Biodistribution simulations were performed based on a recently published mathematical model for a 10- and 100-fold lower monovalent K(D). The therapeutic index was compared to the therapeutic index which is achieved using the actual antibody. The simulations indicate that a considerably increased therapeutic index can be obtained by decreasing the dissociation constant.A reduction of the K(D) to 10-fold or 100-fold lower values would lead to an improvement of the therapeutic index, by a factor of 2.4-5 and 2.4-6.5 respectively. To investigate the predicted improvement of the radioimmunotherapy, new anti-CD66 antibodies with lower dissociation constants should be developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Affinity Constant of Anti-human IgG Monoclonal Antibodies by an ELISA-based Method

Background: The affinity of an antibody to its antigen is a crucial parameter in its biological activity and performance of an immunoassay such as ELISA. Affinity of most IgG specific MAbs are often determined by methods which require labeling of either antigen or antibody, and are sometimes difficult to control, do not always lead to the expected signal and often result in immunological modifi...

متن کامل

Application of Chemometrics in determination of the effects of ionic and non-ionic surfactants on ac-id dissociation constant (pKa) of Meloxicam using spectrophotometric method

The purpose of this study was to determine the acid dissociation constants (pKa) of meloxicam in the presence of various surfactants including sodium lauryl sulfate (SLS) as an anionic surfactant, cetyltrimethylammonium bromide (CTAB) as a cationic surfactant and Triton® TX-100 (TX-100) as a non-ionic surfactant in different pre-determined concentrations. The related pKa was determined spec...

متن کامل

Size Dependence of the Elastic Properties of Pd Nanowire: Molecular Dynamics Simulation

The mechanical properties including elastic stiffness constants as well as bulk modulus of Palladium (Pd) nanowire were calculated in the constant temperature and pressure (NPT), ensemble by molecular dynamics (MD) simulation technique. The quantum Sutton-Chen (Q-SC) many-body potential was used to calculate the cohesive energy as well as forces experience by every atoms. The temperature and pr...

متن کامل

99mTc Direct radiolabeling of PR81, a new anti-MUC1 monoclonal antibody for radioimmunoscintigraphy

  Introduction: Monoclonal antibodies labeled mainly with 99mTc are being widely used as imaging agents in nuclear medicine. Recently PR81 was introduced as a new murine anti-MUC1 MAb against human breast carcinoma. This antibody reacts with the tandem repeat of 20-mer peptide of protein backbone, and is of IgG1 class, with an affinity of 2.19×10-8 M-1. Due to high sp...

متن کامل

اندازه گیری ثابت تمایل (افینیتی) آنتی بادی مونوکلونال IgG ضد آنزیم الکالین فسفاتاز با استفاده از روش الیزا

Background and Aim: The affinity of an antibody with its antigen is a crucial parameter in its biological activity and carrying out immunologic tests such as radioimmunoassay (RIA) and immunohistochemistry. This study was done in our laboratory at Tarbiat Modarres University to measure the affinity constant of specific monoclonal antibodies/MAB (A1G8F7) with alkaline phosphatase enzyme produced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Zeitschrift fur medizinische Physik

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2011