Reliability of the Woodway Curve(TM) Non-Motorized Treadmill for Assessing Anaerobic Performance.
نویسندگان
چکیده
A curved treadmill offers a practical method of assessing anaerobic power by enabling unrestricted running motion and greater sport specificity. The purpose of this research was to determine reliability of a curved treadmill (cTM) sprint test and to compare performance measures to the traditional Wingate anaerobic power test (WAnT) performed on a cycle ergometer. Thirty-two recreationally active men and women (22.4 ± 2.8 yrs; 1.73 ± 0.08 m; 74. 2 ± 13.2 kg) performed four familiarization trials on cTM, followed by two randomly assigned experimental trials consisting of one 30-second maximum effort on either cTM or WAnT. Each trial was separated by at least 48 hours. Repeated measures analysis of variance (ANOVA), interclass correlations (ICC), standard error of measurement (SEM), and minimal differences (MD) were used to determine reliability of familiarization trials on cTM, and Pearson product moment correlations were calculated to compare cTM and WAnT. ANOVA results showed significant differences (p < 0.05) during the four familiarization trials. Post hoc analysis showed significant differences (p < 0. 05) between the first two trials. Familiarization trials 3 and 4 showed a high reliability for each performance variable (distance: ICC2,1 = 0.969, %SEM = 2.645, p = 0.157; mean velocity: ICC2,1 = 0. 969, %SEM = 2.622, p = 0.173; peak velocity: ICC2,1 = 0.966, %SEM = 3.142, p = 0.033; mean power: ICC2,1 = 0.940, %SEM = 4.140, p = 0.093; and peak power: ICC2,1 = 0.887, %SEM = 11.244, p = 0.669). Participants elicited an average peak power of 1050.4 ± 338.5 Watts on cTM and 1031.4 ± 349.8 Watts on WAnT. Pearson product moment coefficients indicated high correlations between peak power, mean power, and peak velocity (r = 0.75, p < 0.001; r = 0.84, p < 0.001; and r = 0.76, p < 0. 001, respectively) derived from cTM and WAnT. In conclusion, results suggest that after two familiarization trials, cTM is a reliable sprint test for recreationally active men and women. In addition, there are strong relationships between cTM and WAnT in assessing anaerobic performance. Key pointsThe Woodway Curve 3.0(TM) is a non-motorized treadmill utilizing a curved platform which allows individuals to simulate an unrestricted sprint test in a laboratory setting, offering a practical and sport specific method of assessing anaerobic power.The curved treadmill provides a reliable sprint test for recreationally active men and women.There are strong relationships between the curved treadmill and cycle ergometer in assessing anaerobic performance.
منابع مشابه
Sprinting performance on the Woodway Curve 3.0 is related to muscle architecture.
To determine if unilateral measures of muscle architecture in the rectus femoris (RF) and vastus lateralis (VL) were related to (and predictive of) sprinting speed and unilateral (and bilateral) force (FRC) and power (POW) during a 30 s maximal sprint on the Woodway Curve 3.0 non-motorized treadmill. Twenty-eight healthy, physically active men (n = 14) and women (n = 14) (age = 22.9 ± 2.4 years...
متن کاملSpeed, Force and Power Values Produced from a Non-motorized Treadmill Test Are Related to Sprinting Performance.
The relationships between 30m sprint time and performance on a non-motorized treadmill test, as well as a vertical jump test were determined in the present investigation. Seventy-eight physically active men and women (22.9±2.7 y; 73.0±14.7 kg; 170.7±10.4 cm) performed a 30-s maximal sprint on the Curve™ non-motorized treadmill (TM) following one familiarization trial. Pearson product-moment cor...
متن کاملA self-paced intermittent protocol on a non-motorised treadmill: a reliable alternative to assessing team-sport running performance.
This study assessed the reliability of a 'self-paced' 30-min, team-sport running protocol on a Woodway Curve 3.0 non-motorised treadmill (NMT). Ten male team-sport athletes (20.3 ± 1.2 y, 74.4 ± 9.7 kg, VO2peak 57.1 ± 4.5 ml·kg(-1)·min(-1)) attended five sessions (VO2peak testing + familiarisation; four reliability trials). The 30-min protocol consisted of three identical 10-min activity blocks...
متن کاملEffect of Fluid Temperature and Volume on Thermoregulation in the Heat
The link between thermoregulation, hydration status, and exercise performance in hot humid environments is controversial. The purpose of this study was to evaluate the effects of volume and temperature of ingested fluid on hydration status, thermoregulation and exercise performance. Recreationally active males (N=11, 24.7±5.9 years; VO2max=58.2±6.0 mL/kg/min) completed two 3-hour intermittent e...
متن کاملReproducibility of Determining Anaerobic Capacity Using Treadmill Ergometry
To implement a method measuring anaerobic capacity within the field of training control, the reproducibility of the results is of deciding significance. In this study, we examined the test-retest-reliability of the most commonly used method for measuring anaerobic capacity to date, modified according to Monod and Scherrer, on a motorized treadmill. Ten healthy, athletically active, male partici...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 12 1 شماره
صفحات -
تاریخ انتشار 2013