Two-year follow-up of the Artisan/Verisyse iris-supported phakic intraocular lens for the correction of high myopia.

نویسندگان

  • Majid Moshirfar
  • Huck A Holz
  • Don K Davis
چکیده

PURPOSE To evaluate the implantation of Artisan/Verisyse phakic intraocular lenses (pIOLs) (Advanced Medical Optics) as an effective and safe method for the correction of high myopia. SETTING Department of Ophthalmology, John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS This retrospective outcomes trial examined the implantation of Artisan/Verisyse pIOLs in 85 highly myopic eyes (mean spherical equivalent -12.2 diopters). Patients were followed for 2 years and examined postoperatively at 1,6,12, and 24 months. Data collected included best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), corneal endothelial cell density, and adverse events. RESULTS Six months postoperatively, 5 (7%) eyes lost 1 line of the BSCVA; no eye lost 2 or more lines. The UCVA was better than 20/40 in 83% of eyes and better than 20/25 in 32%. Endothelial cell density decreased by 3.3% and 6.5% over the 1-year and 2-year intervals, respectively. Glare and halos, the most common complications of surgery, were reported by 6% of patients at 1 month and by 3% at 2 years. CONCLUSION Implantation of the Verisyse/Artisan pIOL yielded accurate refractive results with acceptable safety in highly myopic eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iris-fixated phakic intraocular lens implantation for correction of high myopia in microspherophakia.

We report the refractive correction of high myopia in a 23-year-old patient with idiopathic microspherophakia using iris-fixated phakic intraocular lenses (pIOLs) (Verisyse/Artisan). Four years after bilateral implantation, the uncorrected distance visual acuity was 20/25 with a correction of 20/20(-1) in both eyes. No intraoperative or postoperative complications occurred. Iris-fixated pIOLs a...

متن کامل

Iris-supported phakic lenses (rigid vs foldable version) for treating moderately high myopia: randomized paired eye comparison.

PURPOSE To compare refractive performance of Artisan (Ophtec, Groningen, The Netherlands) or Verisyse phakic intraocular lens and its foldable version, Artiflex (Ophtec), for the correction of moderately high myopia. DESIGN Randomized pilot study. METHODS setting: Institutional practice. patient population: Thirty-one patients with myopia that ranged from -6 to -14 diopters (D). interventio...

متن کامل

Efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia.

AIM To evaluate efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia. METHODS This prospective clinical study included 40 eyes from 29 patients, who underwent implantation of Verisyse for correction of myopia from -6.00 to -14.50 diopters (D) in the Eye Clinic ''Svjetlost'', Sarajevo, from January 2011 to January 2014. Uncorrected distance visual ...

متن کامل

Correction of myopia of 7 to 24 diopters with the Artisan phakic intraocular lens: two-year follow-up.

PURPOSE To evaluate the safety and efficacy of the iris claw phakic intraocular lens (Artisan; Ophtec BV, Groningen, The Netherlands) in patients with high myopia. METHODS Between May 1999 and July 2001, 93 Artisan phakic intraocular lenses (IOLs) were implanted in 60 patients affected by high myopia. All patients underwent 24-month follow-up. The power of the lenses ranged from -7.5 to -22.0...

متن کامل

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

PURPOSE To evaluate variations in the position of the phakic iris claw lens (Artisan, Verisyse) and the natural crystalline lens during the accommodation process. METHODS We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris cla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2007