Study of HF Production in BaBar Resistive Plate Chambers

نویسندگان

  • H. R. Band
  • F. Bellini
  • R. Covarelli
  • E. Di Marco
  • A. D’Orazio
  • F. Ferroni
  • Li Gioi
  • L. Lopez
  • F. Polci
چکیده

The BaBar detector has operated over 200 2nd generation Resistive Plate Chambers (RPCs) in the forward endcap since 2002. Many chambers have increased noise rates and high voltage currents. These aging symptoms are correlated with the integrated RPC current as expected, but also depend on the rate and direction of the gas flow, indicating that pollutants produced in the gas can accelerate aging of downstream RPC surfaces. HF produced by decomposition of the Freon 134a component of the BaBar RPC gas in electric discharges has been proposed as the main pollutant. This paper presents measurements of HF production and absorption rates in BaBar RPCs. Since many of the highest rate chambers in the forward endcap were converted to avalanche mode operation, a comparison of HF production in streamer and avalanche mode RPCs is made. Correlations between the HF production rate and other chamber operating conditions were also explored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resistive Plate Chamber Performance in the BaBar IFR System

The BaBar Collaboration has operated a system covering over 2000 m with resistive plate chambers for nearly three years. The chambers are constructed of bakelite sheets separated by 2 mm. The inner surfaces are coated with linseed oil. This system provides muon and neutral hadron detection for BaBar. Installation and commissioning were completed in 1998, and operation began mid-1999. While init...

متن کامل

Resistive plate chambers in running and future experiments

This document surveys the RPC-based detection systems of running and future collider experiments focusing on the implications of the choice of some basic detector features: number of gaps, electrode material and operating mode. The muon identification systems of the B-factory experiments BaBar and Belle is described and the RPC performance since the first operation of the detectors is briefly r...

متن کامل

Mechanisms affecting performance of the BaBar Resistive Plate Chambers and searches for remediation

The BaBar experiment at PEPII relies on the Instrumentation of the Flux Return (IFR) for both muon identification and KL detection. The active detector is composed of Resistive Plate Chambers (RPC’s) operated in streamer mode. Since the start of operation the RPC’s have suffered persistent efficiency deterioration and dark current increase problems. The "autopsy" of bad BaBar RPC’s revealed tha...

متن کامل

BaBar forward endcap RPCs

The BaBar detector has operated over 2000m of resistive plates chambers (RPCs) as muon and neutral hadron detectors since 1999. Most of the RPCs of the original production underwent a significant efficiency loss and many are now completely inefficient. During the summer 2002 new RPCs from a recent production were therefore installed to replace the old chambers in the forward endcap. The experie...

متن کامل

BABAR Muon System

The BABAR detector, at the Stanford Linear Accelerator Center is a general purpose detector for the study of e+e− interactions at the Υ(4S) resonance. BABAR’s muon detection system consists of two parts: a hexagonal barrel region and two planar endcap regions each containing 18 layers of iron (∼ 3.6λ), with resistive plate chambers within the inter-iron gaps. These chambers have suffered deteri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008