Miniopen Oblique Lateral L5-S1 Interbody Fusion: A Report of 2 Cases
نویسندگان
چکیده
Extreme lateral interbody fusion (XLIF) has been widely used for minimally invasive anterior lumbar interbody fusion (ALIF), but an approach to L5-S1 is difficult because of the iliac crest. In the current study, we present 2 cases using minimally invasive oblique lateral interbody fusion (OLIF) of L5-S1. The patients showed foraminal stenosis between L5 and S1 and severe low back and leg pain. The patients were placed in a lateral decubitus position and underwent OLIF surgery (using a cage and bone graft from the iliac crest) without posterior decompression. Posterior screws were used in the patients. Pain scores significantly improved after surgery. There was no spinal nerve, major vessel, peritoneal, or urinary injury. OLIF surgery was minimally invasive and produced good surgical results without complications.
منابع مشابه
Morphometric anatomy of the lumbar sympathetic trunk with respect to the anterolateral approach to lumbar interbody fusion: a cadaver study.
BACKGROUND An approach to lateral lumbar interbody fusion (LLIF) utilizing an oblique corridor anterior to the psoas muscle was first described by Mayer in 1997 and subsequently by other authors. The only consistent structure of note in this corridor is the lumbar sympathetic trunk (LST), which at times must be mobilized in order to perform a discectomy and interbody fusion, thereby placing the...
متن کاملAnterior dislocation of fusion cage after minimal invasive transforaminal lumbar interbody fusion (MI-TLIF): A case report
This report is a rare case of a lumbar interbody fusion cage dislocation in the procedure of Minimal Invasive Transforaminal Lumbar Interbody Fusion surgery (MI-TLIF) for spondylolisthesis of segment L5/S1. A 65-year-old lady underwent MI-TLIF surgery, and the interbody fusion cage was dislocated forward into retroperitoneal space. The cage was extraction with lateral approach and replaced by l...
متن کاملTHE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY
The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...
متن کاملImaging Anatomical Research on the Operative Windows of Oblique Lumbar Interbody Fusion
To provide applied anatomical evidence of the preoperative assessment of oblique lumbar interbody fusion (OLIF), the anatomical parameters of the OLIF operative window were observed through computed tomography angiography (CTA). We selected imaging data from 60 adults (30 males, 30 females) who underwent abdominal CTA and T12-S1 vertebral computed tomography (CT) with three-dimensional reconstr...
متن کاملSB Charité Disc Replacement Report of 60 Prospective Randomized Cases in a U . S . Center Paul
Sixty patients with one-level discogenic pain confirmed by plain radiography, magnetic resonance imaging, and provocative discography for degenerative disc disease were randomized: one-third BAK anterior interbody fusion and two-thirds anterior SB Charité artificial disc replacement. The mean age was 40.3 years (range 21–56 years). Nineteen cases were at L4–L5 and 41 cases were at L5–S1. Ninete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014