Experimental tonography on enucleated human eyes. II. The loss of intraocular fluid caused by tonography.

نویسندگان

  • J H Eriksen
  • T Odberg
چکیده

In clinical work, the loss of intraocular fluid caused by tonography (dV) is usually calculated according to the formula of Grant and Friedenwald. The validity of this formula has been tested by comparing the dV calculated from known factors in the formula with the dV measured directly on enucleated eyes. Our results show a good correlation between the two methods, especially when the rigidity coefficient at the beginning of tonography is used in the calculations. It is concluded from our experiments here and in our previous paper that the theoretical foundation of tonography in principle is valid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental tonography on enucleated human eyes. I. The validity of Grant's tonography formula.

When newer tables for parameters in Grant's formula for tonography are used, one obtains far higher values for the outflow facility than those generally accepted. The aim of this iinvestigation has, therefore, been to test the validity of the tonography formula. The outflow facility determined by constant-rate perfusion in enucleated eyes has been compared with the results of tonography on the ...

متن کامل

The effect of miotics on the intraocular pressure of conscious owl monkeys

1. Nissen, O. I., and Hoppe, R.: The facility of aqueous outflow calculated from the rate of fall in applanation pressure after intravenous acetazolamide in man, Acta Ophthalmol. 52: 390, 1974. 2. Nissen, O. I.: The immediate response in applanation pressure to intravenous acetazolamide in primary glaucomas and glaucoma suspects, Acta Ophthalmol. 53: 537, 1975. 3. Grant, W. M.: Tonographic meth...

متن کامل

Phosphate and Protein Concentrations of Intraocular Fluids. I. Effect of Carbonic Anhydrase Inhibition in Young and Old Rabbits.

The effects of a carbonic anhydrase inhibitor, dichlorphenamide, on the phosphate and protein concentrations of intraocular fluids have been studied. The administration of dichlorphenamide caused a marked increase in phosphate concentration of posterior and anterior aqueous humors. The changes in steady-state concentrations were compatible with a decrease in the flow coefficient of approximatel...

متن کامل

Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography

Purpose It is not known if outflow facilities measured by pneumatonography and Schiøtz tonography are interchangeable. In this study we compared outflow facility measured by pneumatonography to outflow facility measured by digital Schiøtz tonography. Methods Fifty-six eyes from 28 healthy participants, ages 41 to 68 years, were included. Intraocular pressure (IOP) was measured in the sitting ...

متن کامل

[Tensilon tonography in the diagnosis of myasthenia gravis].

The concomitant intravenous administration of Tensilon during tonography was performed on a group of 15 myasthenic patients and ten "control" subjects, including patients with oculoparesis of known cause other than myasthenia. The myasthenic group uniformly responded with increases of intraocular pressure. There was no instance of this response in nonmyasthenic subjects when challenged with Ten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 14 12  شماره 

صفحات  -

تاریخ انتشار 1975