Use of Proplast II as a subperiosteal implant for the correction of anophthalmic enophthalmos.
نویسندگان
چکیده
BACKGROUND A variety of autogenous and alloplastic materials have been used as subperiosteal implants to correct anophthalmic enophthalmos. Proplast II is a synthetic porous composite of Teflon polymer and alumina. Proplast II offers a number of advantages over other commonly used alloplastic materials such as silicone and polymethyl methacrylate. It is light, porous, resilient, malleable, and easy to shape. It can be readily sterilised after shaping. It has been found to integrate with the surrounding tissues, thereby minimising the risk of subsequent implant migration and extrusion. METHODS Proplast II was used as a subperiosteal implant in a total of 15 anophthalmic patients during the period June 1990 to March 1994. The indication for this procedure in all patients was poor orbital volume replacement despite the prior insertion of an adequately sized spherical socket implant. RESULTS The results were excellent with a good correction of preoperative upper eyelid sulcus deformity. There were no operative complications nor any serious postoperative complications. The implants were well tolerated. CONCLUSION Proplast II can be highly recommended for use as a subperiosteal implant.
منابع مشابه
Correction of superior sulcus deformity and enophthalmos with porous high-density polyethylene sheet in anophthalmic patients.
PURPOSE Superior sulcus deformity is the main cosmetic problem in anophthalmic patients. Many methods of correcting enophthalmos have been reported, especially in patients with orbital wall fracture. The purpose of this study is to review the long term results of effectiveness in superior sulcus deformity correction by subperiosteal Medpor sheet implantation in anophthalmic patients. METHODS ...
متن کاملCorrection of Anophthalmic Enophthalmos with a Three-Staged Procedure: Two Case Reports
Surgical correction of an anophthalmic enophthalmos secondary to inappropriate repair of the eye socket involves several difficult aesthetic issues associated with long-term use of a poorly fitting prosthetic eye. In this paper, we present two cases of anophthalmic enophthalmos. During the treatment of the first patient, unsatisfactory cosmetic problems including lower eyelid retraction, hypogl...
متن کاملCorrection of enophthalmos and deep supratarsal sulcus by posterior subperiosteal glass bead implantation.
متن کامل
Orbital Volume Augmentation with Calcium Hydroxyapatite Filler in Anophthalmic Enophthalmos
PURPOSE To report the long-term results of orbital volume augmentation using calcium hydroxyapatite filler injections in patients with anophthalmic sockets. METHODS Twelve eligible patients with post-enucleation socket syndrome (PESS) and small orbital volumes were included in our study. In this investigation, 1.5 mL injectable calcium hydroxyapatite (Radiesse) was utilized in an off-label ap...
متن کاملRetroseptal structural fat grafting to correct paediatric post- traumatic enophthalmos
Introduction Orbital volume deficiency is caused by various diseases and it can be present in different clinical scenarios. Orbital volume replacement in the posttraumatic enophtalmos is currently addressed by different surgical methods. Several autologous tissues and alloplastic materials have been used. The purpose of this article is to introduce our experience in the management of 8 complex ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 79 9 شماره
صفحات -
تاریخ انتشار 1995