A flexible multicamera visual-tracking system for detecting and correcting motion-induced artifacts in cardiac SPECT slices.
نویسندگان
چکیده
Patient motion is inevitable in SPECT and PET due to the lengthy period of time patients are imaged. The authors hypothesized that the use of external-tracking devices which provide additional information on patient motion independent of SPECT data could be employed to provide a more robust correction than obtainable from data-driven methods. Therefore, the authors investigated the Vicon MX visual-tracking system (VTS) which utilizes near-infrared (NIR) cameras to stereo-image small retroreflective markers on stretchy bands wrapped about the chest and abdomen of patients during cardiac SPECT. The chest markers are used to provide an estimate of the rigid-body (RB) motion of the heart. The abdomen markers are used to provide a signal used to bin list-mode acquisitions as part of correction of respiratory motion of the heart. The system is flexible in that the layout of the cameras can be designed to facilitate marker viewing. The system also automatically adapts marker tracking to employ all of the cameras visualizing a marker at any instant, with visualization by any two being sufficient for stereo-tracking. Herein the ability of this VTS to track motion with submillimeter and subdegree accuracy is established through studies comparing the motion of Tc-99m containing markers as assessed via stereo-tracking and from SPECT reconstructions. The temporal synchronization between motion-tracking data and timing marks embedded in list-mode SPECT acquisitions is shown to agree within 100 ms. In addition, motion artifacts were considerably reduced in reconstructed SPECT slices of an anthropomorphic phantom by employing within iterative reconstruction the motion-tracking information from markers attached to the phantom. The authors assessed the number and placement of NIR cameras required for robust motion tracking of markers during clinical imaging in 77 SPECT patients. They determined that they were able to track without loss during the entire period of SPECT and transmission imaging at least three of the four markers on the chest and one on the abdomen bands 94% and 92% of the time, respectively. The ability of the VTS to correct motion clinically is illustrated for ten patients who volunteered to undergo repeat-rest imaging with the original-rest SPECT study serving as the standard against which to compare the success of correction. Comparison of short-axis slices shows that VTS-based motion correction provides better agreement with the original-rest-imaging slices than either no correction or the vendor-supplied software for motion correction on, our SPECT system. Comparison of polar maps shows that VTS-based motion-correction results in less numerical difference on average in the segments of the polar maps between the original-rest study and the second-rest study than the other two strategies. The difference was statistically significant for the comparison between VTS-based and clinical vendor-supplied software correction. Taken together, these findings suggest that VTS-based motion correction is superior to either no-motion correction or the vendor-supplied software the authors investigated in clinical practice.
منابع مشابه
اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملAssessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]
Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملMyocardial perfusion SPECT: Perfusion quantification
Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically. Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 36 5 شماره
صفحات -
تاریخ انتشار 2009