Characterization of ultrasound-potentiated fibrinolysis in vitro.
نویسندگان
چکیده
We have characterized the effects of ultrasound on fibrinolysis in vitro to investigate the mechanism of ultrasonic potentiation of fibrinolysis and to identify potentially useful ultrasound parameters for therapeutic application. Radiolabeled clots in thin walled tubes were exposed to ultrasound fields in a water bath at 37 degrees C, and lysis was measured by solubilization of radiolabel. Ultrasound accelerated lysis of plasma, whole blood, and purified fibrin clots mediated by recombinant tissue-type plasminogen activator (rt-PA), urokinase, or streptokinase, but ultrasound by itself caused no clot solubilization. The degree of ultrasonic potentiation was dependent on plasminogen activator concentration, increasing from 2.2-fold at a streptokinase concentration of 75 U/mL to 5.5-fold at 250 U/mL in a 1 MHz ultrasound field at 4 W/cm2. Ultrasound exposure resulted in heating due to absorption by the plastic tube, but the temperature increase was insufficient to account for the increase in clot lysis rate, indicating that the primary effect was nonthermal. Ultrasound did not accelerate hydrolysis of a peptide substrate by rt-PA and did not alter the rate of plasmic degradation of fibrinogen, indicating that the augmentation of enzymatic fibrinolysis required the presence of a fibrin gel. The acceleration of fibrinolysis by ultrasound was greater at higher intensities and duty cycles and was maximum at frequencies between 1 and 2.2 MHz, but decreased at 3.4 MHz. These findings suggest that ultrasound accelerates enzymatic fibrinolysis by increasing transport of reactants through a cavitation-related mechanism.
منابع مشابه
Enhancement of fibrinolysis in vitro by ultrasound.
The effect of ultrasound on the rate of fibrinolysis has been investigated using an in vitro system. Plasma or blood clots containing a trace label of 125I fibrin were suspended in plasma containing plasminogen activator and intermittently exposed to continuous wave 1-MHz ultrasound at intensities up to 8 W/cm2. Plasma clot lysis at 1 h with 1 microgram/ml recombinant tissue plasminogen activat...
متن کاملEnhancement of fibrinolysis with 40-kHz ultrasound.
BACKGROUND Ultrasound at frequencies of 0.5 to 1 MHz and intensities of > or =0.5 W/cm2 accelerates enzymatic fibrinolysis in vitro and in some animal models, but unacceptable tissue heating can occur, and limited penetration would restrict application to superficial vessels. Tissue heating is less and penetration better at lower frequencies, but little information is available regarding the ef...
متن کاملMolecular mechanisms of the effect of ultrasound on the fibrinolysis of clots.
BACKGROUND Ultrasound accelerates tissue-type plasminogen activator (t-PA)-induced fibrinolysis of clots in vitro and in vivo. OBJECTIVE To identify mechanisms for the enhancement of t-PA-induced fibrinolysis of clots. METHODS Turbidity is an accurate and convenient method, not previously used, to follow the effects of ultrasound. Deconvolution microscopy was used to determine changes in st...
متن کاملBroad-Beam Ultrasound for Acceleration of Struvite Calculi Dissolution Using Citric Acid-Based Chemolytic Agents
A computer-controlled broad-beam ultrasound system is presented that accelerates struvite stone chemolysis in vitro. Hemiacidrin chemolysis was greatly potentiated and was linearly dependent on stone surface area and total ultrasound time. Dissolution also was dependent on citric acid concentration and solution pH, with only minimal dissolution above pH 4.2. Citrate concentrations of 12% provid...
متن کاملUltrasound improves tissue perfusion in ischemic tissue through a nitric oxide dependent mechanism.
Ultrasound accelerates enzymatic fibrinolysis in vitro and in animal models and may be used as an adjunct to thrombolytic therapy. Ultrasound can also affect vascular tone directly, and we have now investigated the effect of ultrasound on tissue perfusion in a rabbit model of acute muscle ischemia to characterize the magnitude and temporal course of vasodilation and determine its mechanism. Aft...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood
دوره 81 10 شماره
صفحات -
تاریخ انتشار 1993