Common complications of deep lamellar keratoplasty in the early phase of the learning curve

نویسنده

  • Mohamed Hosny
چکیده

PURPOSE To evaluate and record the common complications that face surgeons when they perform their first few series of deep lamellar keratoplasty and measures to avoid these. SETTING Dar El Oyoun Hospital, Cairo, Egypt. METHODS Retrospective study of the first 40 eyes of 40 patients carried out by two corneal surgeons working in the same center. All patients were planned to undergo a deep anterior lamellar keratoplasty using the big bubble technique. Twelve patients suffered from keratoconus while 28 patients had anterior corneal pathologies. Recorded complications were classified as either intraoperative or postoperative. RESULTS Perforation of Descemet's membrane was the most common intraoperative complication. It occurred in nine eyes (22.5%): five eyes (12.5%) had microperforations while four eyes (10%) had macroperforations, three eyes (7.5%) had central perforations, and six eyes (15%) had peripheral perforations. Other complications included incomplete separation of Descemet's membrane and remnants of peripheral stromal tissue. Postoperative complications included double anterior chamber which occurred in four eyes (10%) and Descemet's membrane corrugations. Postoperative astigmatism ranged from 1.25 to 4.5 diopters with a mean of 2.86 diopters in the whole series, but in the six cases with identified residual stroma in the periphery of the host bed, the astigmatism ranged from 2.75 to 4.5 diopters with a mean of 3.62 diopters. CONCLUSION Deep lamellar keratoplasty is sensitive to procedural details. Learning the common complications and how to avoid them helps novice surgeons to learn the procedure faster.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty

Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...

متن کامل

New technique of Deep Anterior Lamellar Keratoplasty

Deep anterior lamellar keratoplasty (DALK) is a surgical technique for cornea replacement, which the healthy host corneal endothelium is preserved. Keratoconus patients are those who benefit most from a successful DALK procedure, once the endothelium of these patients is usually normal and should therefore be maintained. Several studies comparing visual outcomes between penetrating keratoplasty...

متن کامل

Deep lamellar keratoplasty using viscoelastic dissection.

We describe a technique for performing deep lamellar keratoplasty using viscoelastic dissection. Deep lamellar dissections of the cornea using viscoelastic substances (sodium hyaluronate) were performed on 4 eyes of 4 patients. One patient with keratoconus and another with corneal scarring underwent lamellar keratoplasty using the technique as the sole procedure for visual rehabilitation. Two p...

متن کامل

Melanoma detection with a deep learning model

Background: Skin cancer is one of the most common forms of cancer in the world and melanoma is the deadliest type of skin cancer. Both melanoma and melanocytic nevi begin in melanocytes (cells that produce melanin). However, melanocytic nevi are benign whereas melanoma is malignant. This work proposes a deep learning model for classification of these two lesions.    Methods: In this analytic s...

متن کامل

Easy Bubble: Pachymetry-assisted Big-Bubble Deep Anterior Lamellar Keratoplasty

We present a simple, effective and reproducible technique for deep anterior lamellar keratoplasty. Using a diamond knife, set at 90% of corneal thickness (90 degrees meridian), at the limbus a radial incision was made and a corneal pocket was created. A specially designed cannula was placed deep into the corneal stroma and air was injected for stromal dissection. The air bubble pushed down Desc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011