Thin is better!: ultrathin cryosection immunocytochemistry.

نویسندگان

  • Toshihiro Takizawa
  • John M Robinson
چکیده

In immunofluorescence microscopy (IFM), the repression of out of focus fluorescence signal is crucial in order to obtain high-resolution images. One option to acquire high vertical resolution (z-axis resolution) is to produce optical sections with a confocal microscope. The z-axis resolution usually obtained with confocal microscopy of biological samples is about 500 nm. Another option is to produce very thin sections with a cryo-ultramicrotome (physical sections). The ultrathin cryosections we employ are about 100 nm in thickness: thus all of the fluorescence must come from within this 100 nm thickness. The use of ultrathin cryosections permits the acquisition of extremely high-quality images and minimizes the possibility for false localization in IFM (Fig. 1). Ultrathin cryosections can be applied to immunoelectron microscopy (IEM) as well as IFM (Fig. 2). We show new methods of ultrathin cryosection immunocytochemistry(1-3). Human full-term placentas were fixed with 4% paraformaldehyde, solidified with 10% gelatin, infiltrated with 2.3 M sucrose, and then frozen in liquid nitrogen. Ultrathin cryosections were cut with a cryo-ultramicrotome and then transferred to glass cover slips for IFM or to nickel grids for IEM. Cryosections were incubated with mouse anti-p230, a trans-Golgi network marker, and subsequently incubated with Alexa 488-labeled goat anti-mouse IgG or with goat anti-mouse 5-nm colloidal gold particles. For visualization and preservation of ultrastructure of cryosections at the electron microscopic level, the sections on grids were postfixed with ferrocyanide-reduced osmium and then stained with uranyl acetate and lead citrate in polyvinyl alcohol(1). Ultrathin cryosection immunocytochemistry should be an important technique for functional genomics research, especially for the analysis of the in situ expression of target molecules(2,3).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoemission measurements of Ultrathin SiO2 film at low take-off angles

The surface and interfacial analysis of silicon oxide film on silicon substrate is particularly crucial in the nano-electronic devices. For this purpose, series of experiments have been demonstrated to grow oxide film on Si (111) substrate. Then these films have been used to study the structure of the film by using X-ray photo emission spectroscopy (XPS) technique. The obtained results indicate...

متن کامل

Regularized shape deformation for image segmentation

This paper presents a new method for image segmentation by deforming the object shape in a template. The deformation process is controlled using a thin-plate spline kernel based regularization method. The proposed method is especially useful for 2D-based segmentation of 3D medical images by treating segmented slices as templates for their neighboring unsegmented slices. We have applied the prop...

متن کامل

Fabrication of antiferromagnetic α-Cr2O3(0001) thin film and influence on magnetism of ultrathin Co film

We have investigated the fabrication of α-Cr2O3(0001) thin film on a Au(111) surface and the effect of the antiferromagnetic feature of α-Cr2O3(0001) on the magnetic properties of ultrathin Co film on α-Cr2O3(0001). Highly oriented α-Cr2O3(0001) thin film is fabricated by oxidizing Cr(110) thin film grown on a Au(111) surface. Upon the oxidization of threefold symmetric Cr(110) thin film, the α...

متن کامل

Influence of preparation design and ceramic thicknesses on fracture resistance and failure modes of premolar partial coverage restorations.

STATEMENT OF PROBLEM Preparation designs and ceramic thicknesses are key factors for the long-term success of minimally invasive premolar partial coverage restorations. However, only limited information is presently available on this topic. PURPOSE The purpose of this in vitro study was to evaluate the fracture resistance and failure modes of ceramic premolar partial coverage restorations wit...

متن کامل

A Device for Ribbon Collection for Array Tomography with Scanning Electron Microscopy

"Array tomography" is a method used to observe the fine structure of cells and tissues in a three-dimensional view. In this method, serial ultrathin sections in the ribbon state (ribbons) are mounted on a solid substrate and observed by scanning electron microscopy (SEM). The method may also be used in conjunction with post-embedding immunocytochemistry. However, it is difficult to mount many s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Nippon Medical School = Nippon Ika Daigaku zasshi

دوره 71 5  شماره 

صفحات  -

تاریخ انتشار 2004