Intermediate-term radiographic and patient outcomes in revision hip arthroplasty with a modular calcar design and porous plasma coating.
نویسندگان
چکیده
This study is a retrospective evaluation of the intermediate-term results of 26 consecutive revision total hip arthroplasties performed with a modular titanium, uncemented femoral component. The average patient age at the time of revision total hip arthroplasty was 72 years, and there were an equal number of males and females. The mean follow-up was 5.7 years (ranging from 4 to 11 years). No re-revision was necessary during this follow-up time. The mean Harris hip score improved significantly (preoperative and postoperative score was 50.7 and 89.6, respectively; P < .001). Postoperatively, Short Form 36 functional scores averaged 67.7 across 9 functional parameters. Our observed low revision rate and favorable patient-reported outcome scores support the continuous use of modular titanium, uncemented femoral components in revision total hip arthroplasty.
منابع مشابه
Short-Term Results of the DePuy Global Unite Platform Shoulder System: A Two-Year Outcome Study
Background: The Global Unite Shoulder System is the next generation of implant from the Depuy Global Shoulderline. The primary feature of the Global Unite is adaptability through the interchangeable modular bodies, modular suturecollars, and stems. Short-term functional and radiographic outcomes of the Global Unite Platform Shoulder Systemwere assessed as well as complication and revision rates...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملLong Term Outcomes of Total Hip Arthroplasty in Young Patients under 30
Background: We aimed to report outcomes of total hip arthroplasty (THA) in very young patients under the year of 30. Methods: Thirty patients (45 hips) with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications. Results: Within a mean fol...
متن کاملMid-Term Review of ADEPT Metal-On-Metal Hip Prosthesis. Functional, Radiological and Metal Ion Analysis
Background: There is much interest regarding metal-on-metal implants in medical and general media. Much of this has been regarding failure of specific implant systems and metal ion toxicity. We present our early mid-term experience of the ADEPT metal-on-metal system which has both modular and non-modular hip options. Methods: Functional assessment, blood metal ion quantification, and radiograph...
متن کاملHydroxyapatite Coating ~ to Porous-Coated Fixation
Fifteen patients had bilateral hip replacement with a porous-coated hip replacement in one hip and in the contralateral hip the same design. which had adjunctive hydroxyapatite coating on the porous coating. These patients were followed for an average of 6.5 years (range, 5-7.9 years). There was no difference in the clinical Harris Hip Scores between the two hips in these patients. The radiogra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 26 8 شماره
صفحات -
تاریخ انتشار 2011