One-year routine application of a new and rapid method based on ultra performance liquid chromatography-tandem mass spectrometry to the analysis of selected pesticides in citrus fruits.
نویسندگان
چکیده
A rapid method has been developed for monitoring five multiclass pesticides commonly used in citrus fruits. The determination is performed by ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS), after extraction with a mixture of ethyl acetate and sodium sulfate. The method has been validated for orange matrix. Mean recoveries obtained were between 74-110% with a repeatability precision of < 7%, intermediate precision of < 10% and reproducibility precision of < 17%. Linearity over the range 0.010-0.150 mg/kg was demonstrated (r(2) > or = 0.99) with limits of quantification (LOQs) of < or = 0.01 mg/kg. Also, an analytical study focused on the stability of pesticide residues in orange extracts under storage was performed. The method has been applied to the analysis of 365 samples from the agricultural area of the Valencian Community (Spain). Of 103 samples that contained pesticide residues, only abamectin in 2 samples and carbendazim in 5 samples slightly exceeded the European maximum residue limits (MRLs).
منابع مشابه
Simultaneous Analysis of Metabolite Residues from Degradation of Dithiocarbamates in Cereals Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Background and Objectives: Dithiocarbamates are groups of fungicides used to control pests of agricultural products. Analysis of these pesticides with liquid and gas chromatography instruments is associated with various problems due to the presence of metal groups in the structure of these compounds. Therefore, one of the ways for analysis the pesticides is to check the level of decomposition...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 25 4 شماره
صفحات -
تاریخ انتشار 2009