Sheathless capillary electrophoresis‐mass spectrometry for anionic metabolic profiling

نویسندگان

  • Mehmet Can Gulersonmez
  • Stephen Lock
  • Thomas Hankemeier
  • Rawi Ramautar
چکیده

The performance of CE coupled on-line to MS via a sheathless porous tip sprayer was evaluated for anionic metabolic profiling. A representative metabolite mixture and biological samples were used for the evaluation of various analytical parameters, such as peak efficiency (plate numbers), migration time and peak area repeatability, and LODs. The BGE, i.e. 10% acetic acid (pH 2.2), previously used for cationic metabolic profiling was now assessed for anionic metabolic profiling by using MS detection in negative ion mode. For test compounds, RSDs for migration times and peak areas were below 2 and 11%, respectively, and plate numbers ranged from 60 000 to 40 0000 demonstrating a high separation efficiency. Critical metabolites with low or no retention on reversed-phase LC could be efficiently separated and selectively analyzed by the sheathless CE-MS method. An injection volume of only circa 20 nL resulted in LODs between 10 and 200 nM (corresponding to an amount of 0.4-4 fmol), which was an at least tenfold improvement as compared to LODs obtained by conventional CE-MS approaches for these analytes. The methodology was applied to anionic metabolic profiling of glioblastoma cell line extracts. Overall, a sheathless CE-MS method has been developed for highly efficient and sensitive anionic metabolic profiling studies, which can also be used for cationic metabolic profiling studies by only switching the MS detection and separation voltage polarity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused-silica capillary

A simple procedure was developed for preparing a carbon-coated fused-silica capillary for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The tapered capillary tip was smeared with a marker pen before coating with carbon using a soft pencil. The layer from the ink of the marker pen was critical to the preparation of the carbon-coated capillary. The fabric...

متن کامل

Comprehensive profiling of free and conjugated estrogens by capillary electrophoresis-time of flight/mass spectrometry.

The biological activity of estrogens is tightly regulated by regioselective phase I/II metabolic transformations that are critical to human health. Current methods for analysis of urinary estrogens are limited by complicated sample pretreatment and/or inadequate specificity for free estrogens and their glucuronide/sulfate conjugates that vary widely in their intrinsic polarity. In this work, di...

متن کامل

A colloidal graphite-coated emitter for sheathless capillary electrophoresis/nanoelectrospray ionization mass spectrometry.

A colloidal graphite-coated emitter is introduced for sheathless capillary electrophoresis/nanoelectrospray ionization time-of-flight mass spectrometry (CE/ESI-TOFMS). The conductive coating can be produced by brushing the capillary tip to construct a fine layer of 2-propanol-based colloidal graphite. The fabrication involves a single step and requires less than 2 min. Full cure properties deve...

متن کامل

A soft on-column metal coating procedure for robust sheathless electrospray emitters used in capillary electrophoresis-mass spectrometry.

An on-column metal coating procedure was developed for sheathless electrospray emitters, based on Justus von Liebig's electroless silver mirror reaction followed by electrochemical deposition of gold onto the silver layer. The coating procedure is straightforward, mild, inexpensive, and can be performed with standard laboratory equipment. A long-term (600 h) stability investigation of the condu...

متن کامل

Sheathless Capillary Electrophoresis-Tandem Mass Spectrometry for Top-Down Characterization of Pyrococcus furiosus Proteins on a Proteome Scale

Intact protein analysis via top-down mass spectrometry (MS) provides the unique capability of fully characterizing protein isoforms and combinatorial post-translational modifications (PTMs) compared to the bottom-up MS approach. Front-end protein separation poses a challenge for analyzing complex mixtures of intact proteins on a proteomic scale. Here we applied capillary electrophoresis (CE) th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2016