Nanoparticles Induce Changes of the Electrical Activity of Neuronal Networks on Microelectrode Array Neurochips

نویسندگان

  • Alexandra Gramowski
  • Juliane Flossdorf
  • Kunal Bhattacharya
  • Ludwig Jonas
  • Margareta Lantow
  • Qamar Rahman
  • Dietmar Schiffmann
  • Dieter G. Weiss
  • Elke Dopp
چکیده

BACKGROUND Nanomaterials are extensively used in industry and daily life, but little is known about possible health effects. An intensified research regarding toxicity of nanomaterials is urgently needed. Several studies have demonstrated that nanoparticles (NPs; diameter < 100 nm) can be transported to the central nervous system; however, interference of NPs with the electrical activity of neurons has not yet been shown. OBJECTIVES/METHODS We investigated the acute electrophysiological effects of carbon black (CB), hematite (Fe2O3), and titanium dioxide (TiO2) NPs in primary murine cortical networks on microelectrode array (MEA) neurochips. Uptake of NPs was studied by transmission electron microscopy (TEM), and intracellular formation of reactive oxygen species (ROS) was studied by flow cytometry. RESULTS The multiparametric assessment of electrical activity changes caused by the NPs revealed an NP-specific and concentration-dependent inhibition of the firing patterns. The number of action potentials and the frequency of their patterns (spike and burst rates) showed a significant particle-dependent decrease and significant differences in potency. Further, we detected the uptake of CB, Fe2O3, and TiO2 into glial cells and neurons by TEM. Additionally, 24 hr exposure to TiO2 NPs caused intracellular formation of ROS in neuronal and glial cells, whereas exposure to CB and Fe2O3 NPs up to a concentration of 10 µg/cm2 did not induce significant changes in free radical levels. CONCLUSION NPs at low particle concentrations are able to exhibit a neurotoxic effect by disturbing the electrical activity of neuronal networks, but the underlying mechanisms depend on the particle type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryopreserved rat cortical cells develop functional neuronal networks on microelectrode arrays.

Neurons growing on microelectrode arrays (MEAs) are promising tools to investigate principal neuronal network mechanisms and network responses to pharmaceutical substances. However, broad application of these tools, e.g. in pharmaceutical substance screening, requires neuronal cells that provide stable activity on MEAs. Cryopreserved cortical neurons (CCx) from embryonic rats were cultured on M...

متن کامل

In Vitro Studies of Neuronal Networks and Synaptic Plasticity in Invertebrates and in Mammals Using Multielectrode Arrays

Brain functions are strictly dependent on neural connections formed during development and modified during life. The cellular and molecular mechanisms underlying synaptogenesis and plastic changes involved in learning and memory have been analyzed in detail in simple animals such as invertebrates and in circuits of mammalian brains mainly by intracellular recordings of neuronal activity. In the...

متن کامل

Neuronal differentiation and synapse formation of PC12 and embryonic stem cells on interdigitated microelectrode arrays: contact structures for neuron-to-electrode signal transmission (NEST).

The development of neuron-microelectrode interfaces (neurochips) is highly desirable for the non-invasive recording of the cellular response to neuroactive drugs as well as the electrical stimulation of nervous tissue by implantable electrodes. A prerequisite for neuron-to-electrode signal transmission (NEST) is the formation of synapse-like contacts between the neuronal cell and the conductive...

متن کامل

Human neurospheres on microelectrode arrays: a model to investigate ionizing radiation effects on neuronal network communication

Ionizing radiation is known to induce numerous effects in cells including cell cycle delay, DNA damage, altered gene expression and cell death. Although there are serious impacts on the organisms, the effects on prenatal development are largely unknown. Data regarding potential biological effects on the prenatal development after in utero radiation exposure predominantly stem from atomic bomb s...

متن کامل

Human Cell-Based Micro Electrode Array Platform for Studying Neurotoxicity

At present, most of the neurotoxicological analyses are based on in vitro and in vivo models utilizing animal cells or animal models. In addition, the used in vitro models are mostly based on molecular biological end-point analyses. Thus, for neurotoxicological screening, human cell-based analysis platforms in which the functional neuronal networks responses for various neurotoxicants can be al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 118  شماره 

صفحات  -

تاریخ انتشار 2010