Relative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent.
نویسندگان
چکیده
We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods correlated (r greater than 0.95). Electrophoresis demonstrated the greatest scatter about the regression line, immunoinhibition the least. For CK-MB quantities near each method's "positive cutoff" indicating myocardial infarction, results by all methods agreed in 95% of samples. To characterize relative increases in CK-MB, we computer-fitted data obtained from each method for serial specimens collected from six acute myocardial infarction patients during myocardial reperfusion. Although for each individual patient the four methods appeared to exhibit parallelism, the methods differed significantly in terms describing their appearance rate, peak-time & fall-off, and time-to-peak activity. Consistent with these data, we found that the relative CK-MB increases at various times after reperfusion, compared with baseline concentrations, are method-dependent. Therefore, when using CK-MB for indicating coronary patency, one must develop specific limits for each method utilized.
منابع مشابه
Time changes of creatine kinase and creatine kinase-MB isoenzyme versus discrimination values in the diagnosis of acute myocardial infarction: what is the optimal method for displaying the data?
We wanted to determine the optimal method for displaying data for the clinical evaluation of patients with possible acute myocardial infarction. Our primary question was, are the time changes (slopes) of the enzyme tests better predictors of disease than the discrimination values, i.e., the cut-off points? We studied 152 patients with and 114 without a diagnosis of acute myocardial infarction i...
متن کاملEffect of HEMADO on Level of CK-MB and LDH Enzymes after Ischemia/Reperfusion Injury in Isolated Rat Heart.
INTRODUCTION Ischemia/Reperfusion (IR) injury mainly causes the increase of enzymes involved in myocytes injury including CK-MB (creatine kinase-MB) isoenzyme and LDH (lactate dehydrogenase). Leakage of CK-MB isoenzyme and LDH from myocardial tissues to blood is indicator of acute myocardial infarction. The aim of this study was to assess the effect of HEMADO on IR injury and its relationship w...
متن کاملUse of creatine kinase MB isoenzyme for diagnosing myocardial infarction when total creatine kinase activity is high.
The usefulness of measuring creatine kinase MB isoenzyme for diagnosing myocardial infarction when activities of total creatine kinase are very high is unclear. We conducted a retrospective study in an urban hospital that serves a largely indigent population. We concentrated on 146 patients whose creatine kinase activity was greater than 1000 U/L (upper limit of normal: 165 U/L for women and 22...
متن کاملCirculating CK-MB and CK-BB isoenzyme after gastrointestinal surgery.
The effect of gastrointestinal surgery on serum creatine kinase activity was studied in 30 patients. The MB isoenzyme was demonstrated in sera of 30% of the patients and BB isoenzyme in 23%. MB content varied from 0.8 to 10.3% of the total creatine kinase activity, and the BB content from 0.6 to 18.4%. The CK-BB was probably of gastrointestinal origin, since gastrointestinal tract contains high...
متن کاملPerformance characteristics of creatine kinase-MB isoenzyme measured with an immunoenzymometric and an immunoinhibition assay in acute myocardial infarction with and without thrombolytic therapy.
In a time study we compared the analytical and clinical performance of the Tandem Icon QSR CK-MB enzyme-immunoassay (Hybritech) (creatine kinase-MB) and a creatine kinase-MB immunoinhibition method (Boehringer Mannheim GmbH) (creatine kinase-B). Two hundred and ninety-nine serum samples from 38 patients suspected of acute myocardial infarction were collected at regular intervals during 48 hours...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 36 8 Pt 1 شماره
صفحات -
تاریخ انتشار 1990