Structure versus function: correlation between outer retinal and choroidal thicknesses measured by swept-source OCT with multifocal electroretinography and visual acuity

نویسندگان

  • Ignacio Flores-Moreno
  • Luis Arias-Barquet
  • Marcos J Rubio-Caso
  • Alex Muñoz-Blanco
  • María Vidal-Martí
  • Jaume Catala-Mora
  • José M Ruiz-Moreno
  • Jay S Duker
  • Josep M Caminal
چکیده

BACKGROUND To correlate retina-choroidal anatomy as assessed via swept-source OCT (SS-OCT) with retinal function as determined by best-corrected visual acuity (BCVA) and multifocal electroretinogram (mfERG). METHODS Thirty-three eyes from 33 patients including 16 with neovascular AMD (nvAMD) and 17 controls were included. Patients were included in the present study after a complete ophthalmologic examination, including BCVA, slit-lamp study, intraocular pressure measurement, dilated fundus examination after tropicamide instillation, SD-OCT, SS-OCT, fundus photographs and mfERG. Age, sex, BCVA, number of anti-VEGF intravitreal injections in the nvAMD group, were recollected. Outer retinal and choroidal thickness were determined at the fovea and 500 μm temporal, superior, nasal and inferior. First-order response from mfERG was collected. P1 amplitude was recorded in R1, R2 and the average of R1 + R2. The measurements recollected from the SS-OCT, mfERG and BCVA were compared. RESULTS Better BCVA was found with thicker outer retina foveal thickness (r = 0.349; P = 0.047), with thicker subfoveal choroidal thickness (r = 0.443; P = 0.010), and with higher amplitude in P1 at R1 (r = 0.346; P = 0.037). Outer retina foveal thickness did not correlate with P1 amplitude at R1 (r = 0.072; P = 0.692), R2 (r = 0.265; P = 0.137) either with the average P1 amplitude at R1 + R2 (r = 0.253; P = 0.156). A thicker subfoveal choroidal thickness was related with higher amplitude in P1 at R1 (r = 0.383; P = 0.028), R2 (r = 0.409; P = 0.018) and the average of R1 + R2 (r = 0.419; P = 0.015). CONCLUSIONS Choroidal thickness demonstrated a positive correlation with retinal function in the sample studied, so a thicker choroid is related to a better retinal function measured with mfERG and BCVA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two Cases of Focal Choroidal Excavation Detected by Spectral-Domain Optical Coherence Tomography

PURPOSE To report the clinical findings of 2 patients with focal choroidal excavation in the macula detected by spectral-domain optical coherence tomography (SD-OCT). METHODS Three eyes of 2 patients with a focal macular choroidal excavation detected by SD-OCT were studied. The eyes were examined by fundus autofluorescence (FAF), fluorescein angiography, fundus-related microperimetry, and mul...

متن کامل

Age-Dependent Morphologic Alterations in the Outer Retinal and Choroidal Thicknesses Using Swept Source Optical Coherence Tomography

PURPOSE To evaluate the age-dependent morphologic alterations in the outer retina and choroid at the macula using swept-source optical coherence tomography (OCT). METHODS Thirty eyes (30 normal subjects; average age, 49 years) were examined; five (age range, third-eighth decades of life) had refractive errors of ±2 diopters or less and no fundus abnormalities. An Early Treatment Diabetic Reti...

متن کامل

Retinal function in best macular dystrophy: relationship between electrophysiological, psychophysical, and structural measures of damage.

PURPOSE To establish structure-function correlations across the visual field, to investigate disease progression in Best macular dystrophy (BMD), by correlating structural damage with retinal function as assessed by the combination of psychophysics and multifocal electrophysiology. METHODS Spatial achromatic and chromatic contrast sensitivities (probing red-green and blue-yellow pathways) wer...

متن کامل

Choroidal thickness measurement by enhanced depth imaging and swept-source optical coherence tomography in central serous chorioretinopathy

BACKGROUND We evaluated subfoveal choroidal thickness measured with two different forms of optical coherence tomography (OCT), enhanced-depth imaging (EDI) and swept-source (SS) OCT, in central serous chorioretinopathy (CSC). METHODS Fifty-six eyes of 48 patients diagnosed with acute or chronic CSC, were studied prospectively. Subfoveal choroidal thickness was measured as the distance between...

متن کامل

Clinical features of bilateral acute idiopathic maculopathy.

PURPOSE To describe the clinical course of bilateral acute idiopathic maculopathy (BAIM), and to analyze its pathophysiology. CASE A 33-year-old Japanese woman presented with a sudden, severe, bilateral visual disturbance following a flu-like illness. She was examined by fluorescein angiography (FA), indocyanine green angiography (IA), scanning laser ophthalmoscopy (SLO), optical coherence to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017