Probabilistic finite element analysis of the uncemented hip replacement--effect of femur characteristics and implant design geometry.
نویسندگان
چکیده
In the present study, a probabilistic finite element tool was assessed using an uncemented total hip replacement model. Fully bonded and frictional interfaces were investigated for combinations of three proximal femurs and two implant designs, the Proxima short stem and the IPS hip stem prostheses. The Monte Carlo method was used with two performance indicators: the percentage of bone volume that exceeded specified strain limits and the maximum nodal micromotion. The six degrees of freedom of bone-implant relative position, magnitude of the hip contact force (L), and spatial direction of L were the random variables. The distal portion of the proximal femurs was completely constrained and some of the main muscle forces acting in the hip were applied. The coefficients of the linear approximation between the random variables and the output were used as the sensitivity values. In all cases, bone-implant position related parameters were the most sensitive parameters. The results varied depending on the femur, the implant design and the interface conditions. Values of maximum nodal micromotion agreed with results from previous studies, confirming the robustness of the implemented computational tool. It was demonstrated that results from a single model study should not be generalised to the entire population of femurs and that bone variability is an important factor that should be investigated in such analyses.
منابع مشابه
Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملEffect of Implant Material Properties on Remodelling of a Composite Hip Stem
INTRODUCTION Stress-shielding following uncemented hip replacement causes bone remodelling due to alteration of the load transfer pathways. The degree of bone resorption is related to the geometry and bending stiffness of the stem. Large diameter, cobalt chrome stems are attributed with producing the most pronounced bone loss. The Epoch hip prosthesis (Zimmer Inc., Warsaw, IN) is a low bending ...
متن کاملDesign Optimization of Hip Resurfacing Prosthesis Using Finite Element Analysis
Hip resurfacing is an alternative to total hip arthroplasty for the young and active patient likely to outlive traditional means of hip joint replacement. To optimize design on the hip resurfacing prosthetic stress profile in the proximal femur after hip resurfacing. The acetabular cup is implanted in much the same fashion as an uncemented total hip arthroplasty, however, implantation of the fe...
متن کاملAnalysis of stress distribution around total hip stems custom-designed for the standardized Asian femur configuration
In total hip replacement (THR), bone resorption related to the foreign body reaction around the implant causes bonding failure at the bone-prosthesis interface and adversely affects the function and longevity of femoral implants. Stress shielding is thought to be one of the possible biomechanical factors that causes bone resorption, and is related to prosthesis design. We therefore investigated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 43 3 شماره
صفحات -