Evaluation of the Xpert MTB/RIF test for the diagnosis of childhood pulmonary tuberculosis in Uganda: a cross-sectional diagnostic study

نویسندگان

  • Moorine Penninah Sekadde
  • Eric Wobudeya
  • Moses L Joloba
  • Willy Ssengooba
  • Harriet Kisembo
  • Sabrina Bakeera-Kitaka
  • Philippa Musoke
چکیده

BACKGROUND The diagnosis of childhood tuberculosis remains a challenge worldwide. The Xpert MTB/RIF test, a rapid mycobacteria tuberculosis diagnostic tool, was recommended for use in children based on data from adult studies. We evaluated the performance of the Xpert MTB/RIF test for the diagnosis of childhood pulmonary tuberculosis using one induced sputum sample and described clinical characteristics associated with a positive Xpert MTB/RIF test. The sputum culture on both Lowenstein-Jensen (LJ) and Mycobacteria Growth Indicator Tube (MGIT) was the gold standard. METHODS We consecutively enrolled 250 Ugandan children aged 2 months to 12 years with suspected pulmonary tuberculosis between January 2011 and January 2012 into a cross-sectional diagnostic study at a tertiary care facility in Uganda. RESULTS We excluded data from 15 children (13 contaminated culture and 2 indeterminate MTB/RIF test results) and analysed 235 records. The Xpert MTB/RIF test had a sensitivity of 79.4% (95% CI 63.2 - 89.7) and a specificity of 96.5% (95% CI 93 - 98.3). The Xpert MTB/RIF test identified 13 of the 14 (92.9%) smear positive-culture positive and 14 of the 20 (70%) smear negative -culture positive cases. The Xpert MTB/RIF identified twice as many cases as the smear microscopy (79.4% Vs 41.2%). Age > 5 years (OR 3.3, 95% CI 1.4 - 7.4, p value 0.005), a history of Tuberculosis (TB) contact (OR 2.4, 95% CI 1.1 - 5.2, p value 0.03), and a positive tuberculin skin test (OR 4.1, 95% CI 1.7 - 10, p value 0.02) was associated with a positive Xpert MTB/RIF test. The median time to TB detection was 49.5 days (IQR 38.4-61.2) for LJ, and 6 days (IQR 5 - 11.5) for MGIT culture and 2 hours for the Xpert MTB/RIF test. CONCLUSION The Xpert MTB/RIF test on one sputum sample rapidly and correctly identified the majority of children with culture confirmed pulmonary tuberculosis with high specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Diagnosis of Childhood Pulmonary Tuberculosis by Xpert MTB/RIF Assay Using Bronchoalveolar Lavage Fluid

In order to evaluate the diagnostic accuracy of the Xpert MTB/RIF assay on childhood pulmonary tuberculosis (PTB) using bronchoalveolar lavage fluid (BALF), we evaluated the sensitivity, specificity, positive predictive value, and negative predictive value of Xpert MTB/RIF assay using BALF in comparison with acid-fast bacilli (AFB) microscopy and Mycobacterium tuberculosis (MTB) culture for dia...

متن کامل

A Comprehensive Evaluation of Xpert MTB/RIF Assay With Bronchoalveolar Lavage Fluid as a Single Test or Combined With Conventional Assays for Diagnosis of Pulmonary Tuberculosis in China: A Two-Center Prospective Study

Introduction: The Xpert MTB/RIF is recommended by the World Health Organization as a first line rapid test for the diagnosis of pulmonary tuberculosis (TB); however, China does not routinely use this test, partially due to the lack of a sufficient number of systematic evaluations of this assay in local patients. The aims of this study were to comprehensively assess the diagnostic performance of...

متن کامل

Evaluation of Cepheid's Xpert MTB/RIF Test on Pleural Fluid in the Diagnosis of Pleural Tuberculosis in a High Prevalence HIV/TB Setting

BACKGROUND Diagnosis of pleural tuberculosis (TB) using routinely available diagnostic methods is challenging due to the paucibacillary nature of the disease. Histopathology and pleural tissue TB culture involves an invasive procedure which requires expertise and appropriate equipment, both often unavailable in many health units. Xpert MTB/Rif test has been widely evaluated in sputum specimens ...

متن کامل

Stool Xpert® MTB/RIF test for the diagnosis of childhood pulmonary tuberculosis at primary clinics in Zimbabwe

OBJECTIVE To evaluate the diagnostic performance of Xpert® MTB/RIF on stool samples from children with clinical suspicion of pulmonary tuberculosis (PTB) at primary care clinics. DESIGN A cross-sectional diagnostic evaluation enrolling 5-16 year olds from whom one induced sputum (IS) sample was tested for microbiological TB confirmation. Results of a single stool sample tested using Xpert wer...

متن کامل

Evaluation of Xpert MTB/RIF in detection of pulmonary and extrapulmonary tuberculosis cases in China

Background: To evaluate the performance of Xpert MTB/RIF assay for direct detection of Mycobacterium tuberculosis (Mtb) and rifampin resistance in pulmonary and extrapulmonary tuberculosis (TB) patients in China. Material/Methods: We prospectively enrolled 506 TB patients to evaluate sensitivity and specificity of Xpert MTB/ RIF by comparing with Mtb culture, fluorescent staining smear microsco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2013