A comparison of methods of evaluating cervical range of motion.

نویسندگان

  • Virginia A Wolfenberger
  • Quynh Bui
  • G Brian Batenchuk
چکیده

OBJECTIVE To determine whether there are differences in results when evaluating cervical range of motion (ROM) with radiographic analysis, a bubble goniometer, and a dual inclinometer and whether particular physical parameters are related to cervical ROM. METHODS We evaluated the cervical ROM of 115 volunteers with each of the 3 clinical methods. Tape measurements of neck girth, distance from chin to sternal notch, and distances from ears to acromion were also recorded, along with sex and age. Interrater and intrarater reliabilities were determined, and the Pearson product moment correlation test and t test were performed on all data. RESULTS Cervical ROM as determined by radiographic analysis was greater than that obtained with either a dual inclinometer or a bubble goniometer. All tape measurements were weakly correlated with all 3 means of cervical ROM evaluation, with the exception of the measurement of ear lobes to acromion, which did not correlate with radiographic analysis. There were also differences found in cervical ROM by sex and by age, with female subjects and younger subjects having a greater ROM. CONCLUSION Compared with a dual inclinometer and a bubble goniometer, radiographic analysis provides a more accurate evaluation of cervical ROM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate Effect of Kinesio-Taping on Cervical Lateral Flexion Range of Motion in Subjects With Myofascial Trigger Point in Upper Trapezius Muscle

Purpose: The purpose of this study was to investigate the effect of kinesio-taping on the range of motion of cervical lateral flexion point in subjects with trigger point in upper trapezius muscle. Methods: A total of 32 subjects with myofascial trigger point in upper trapezius participated in this randomized controlled trial (RCT). The subjects were randomly assigned to two groups: Kinesio-...

متن کامل

The Reliability and Concurrent Validity of Digital Inclinometer, Smartphone Applications, and the Cervical Range of Motion Device for Measuring the Cervical Range of Motion

Objectives: Changes in the Range of Motion (ROM) are essential criteria in determining the severity of spinal disorders and could be effective in predicting pain progression. Instruments to measure the ROM are costly and unavailable in most therapy settings. While there is a tendency in therapists to use their smartphones instead, there is no report to measure the suitability of smartphones to ...

متن کامل

Effects of Kendall Exercise vs. Gong\'s Mobilization on Pain, Range of Motion, Function, and Strength in Cases with Text Neck Syndrome

Objective: To determine the impact of Kendall versus Gong's intervention according to pain sensation, range of movement, function, strength, and posture in cases with text neck syndrome Methods: This randomized clinical trial recruited a sample of 24 patients with text neck syndrome from Fatima Hospital, Sargodha, Pakistan from January to April 2021. The samples were randomly divided into 2 gr...

متن کامل

Predicting the Risk of Hearing Impairment Following the Cervical Spine Diseases by Measuring the Cervical Range of Movements: A Pilot Study

Introduction: Cervical spine abnormalities can affect the ear vessels and or nerves with different mechanisms. Ear dysfunctions following cervical spine injuries can be manifested as hearing loss, vertigo, or tinnitus. Usually, cervical spine injuries can cause pain and Range of Motion (ROM) limitation. The major objective of this study was to determine which cervical ROM limitation was accompa...

متن کامل

Designing, Fabricating, and Testing the Validity and Reliability of the Digital Headband for Cervical Proprioception Assessment: A Descriptive Study

Background and Objectives: Accuracy of proprioceptive input plays an important role in cervical motor control. Several methods have been used to evaluate the accuracy of proprioceptive input as a factor of cervical injury prevention or rehabilitation. The aim of this study was to introduce a new tool for evaluating the accuracy of cervical proprioception and determine its validity and reliabili...

متن کامل

Comparison of Stability Training with and without Positional Release Technique on the Pain, Neck Range of Motion in Men with Chronic Neck Pain

Introduction: Neck pain is the second common musculoskeletal disorder Clinical trial only by back pain. Despite the high prevalence of neck pain, its treatment is still a major challenge. Neck stabilizer training is a technique designed to improve the internal mechanisms of the spine which causes cervical spine stability and invulnerability. On the other hand, manual treatments are low-costly w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of manipulative and physiological therapeutics

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2002