Use of an enzymatic kit method for cholesterol, designed for continuous-flow instrumentation, with discrete bichromatic and centrifugal analyzers.

نویسنده

  • S S Levinson
چکیده

I examined a cholesterol-assay kit ("Autoflo", Biodynamics/bmc) designed for use with continuous-flow instrumentation for its use with some discrete analyzers. At pH 7.2, color develops within 3 min upon exposure to cholesterol, then begins to fade. At pH 8, the color develops more slowly but remains stable for at least 15 min after reaching a maximum. A pH 8.8, the color develops still more slowly and standards and patients' sera behave differently. Reagent at pH 7.2 is preferred because assays can be completed most rapidly, but pH 8 reagent must be used with instruments requiring longer periods of incubation. Cholesterol assays can be performed accurately, rapidly, reproducibly, and at low cost with an Abbott ABA-50 and pH 7.2 reagent or with a Gemeni Centrifugal Analyzer and the pH 8 reagent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A bichromatic method for total bilirubin with a CentrifiChem 400.

We describe a method for the bichromatic determination of total bilirubin with a CentrifiChem 400 centrifugal analyzer with the Boehringer DPD kit. After reading the blank at 620 nm, we read the test at 550 nm. Because only one rotor is required, the analytical time for bilirubin estimations is halved. The proposed method is no more prone to interference by hemoglobin or turbidity than a conven...

متن کامل

An integrated approach to lipid profiling: enzymatic determination of cholesterol and triglycerides with a centrifugal analyzer.

We describe enzymatic methods for determination of cholesterol and triglycerides (triacylglycerols), adapted for use with a centrifugal analyzer. Triglycerides are determined by a two-point kinetic method, which utilizes a single glycerol standard for calibration and provides for a within-run reagent blank correction. The endpoint determination of cholesterol combines the unique blanking capabi...

متن کامل

Continuous-flow enzymatic determination of total serum cholesterol and method standardization with CDC-calibrated pooled sera.

We compared Boehringer Mannheim's enzymatic kit for the continuous-flow (AutoAnalyzer II) determination of serum cholesterol with Technicon's N-24a extraction method. Results for patients' samples analyzed by the enzymatic method were higher than those by the comparison method. To evaluate accuracy in the cholesterol determinations, we enrolled the enzymatic method into the Center for Disease C...

متن کامل

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

Manual and centrifugal analyzer determination of cholesterol and triglycerides with single-vial enzymatic reagents.

We have assessed Calbiochem single-vial enzymatic reagent systems for the analysis for cholesterol and triglycerides, using manual and centrifugal analyzer techniques. Analysis for cholesterol by both techniques had acceptable performance by the short-term criteria of the Center for Disease Control (CDC) during this study carried out under optimal conditions of variance. Analysis for triglyceri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 12  شماره 

صفحات  -

تاریخ انتشار 1977