Some new observations on pulse sequence dependent diffusion related edge enhancement in MR microscopy.

نویسندگان

  • Z H Cho
  • I K Hong
  • Y M Ro
چکیده

Self-diffusion of nuclear spins has been suggested to cause edge enhancement in images especially on a microscopic scale. According to previously published work, theory suggests that edge enhancement is caused by motional narrowing due to the boundaries and spin self-diffusion during the data acquisition period. More careful examination reveals that edge enhancement due to motional narrowing develops only under a few specific conditions. This lack of generality of motional narrowing theory, as well as experimental observations, indicate that edge enhancement due to effects other than motional narrowing alone can exist. It is found that edge enhancement depends greatly on the data acquisition mode; therefore, the images obtained are different depending on the pulse sequence employed. For example, excessive attenuation of DC components due to diffusion can result in edge enhancement in the spin echo signal. However, in the case of FID-like signals, DC components are preserved while positive high frequency parts are attenuated, thereby degrading resolution. The new phenomenon observed has been termed selective spectral suppression since the observed edge enhancement results from the selective attenuation of certain frequency components in the nuclear signals due to diffusion-dependent signal attenuation for a given pulse sequence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

Diffusion imaging of the human brain: a new pulse sequence application for a 1.5-T standard MR system.

We developed a new pulse sequence and investigated whether the anisotropic diffusion in the human brain can be detailed with a standard whole-body MR imager. Apparent diffusion coefficient maps were produced by the proposed sequence using a 1.5-T MR unit. The sequence employed simultaneous application of three orthogonal gradients to achieve an optimal signal attenuation for imaging the brain w...

متن کامل

Studies of weakly restricted diffusion using hyperpolarized He gas in cylindrical cells

Introduction Diffusive motion of nuclei during signal acquisition has a much stronger impact (through, e.g., blurring or edge enhancement [1]) on lung imaging with hyperpolarized gases than on conventional proton MRI. With air space dimensions ranging from tenths of millimeter (alveoli) to centimeters (main bronchi), diffusion regimes may vary from free diffusion to motional averaging or locali...

متن کامل

Advanced cardiac MR imaging of ischemic heart disease.

Important advances in rapid magnetic resonance (MR) imaging technology and its application to cardiovascular imaging have been made during the past decade. High-field-strength clinical magnets, high-performance gradient hardware, and ultrafast pulse sequence technology are rapidly making the vision of a comprehensive "one-stop shop" cardiac MR imaging examination a reality. This examination is ...

متن کامل

Solute Transport for Pulse Type Input Point Source along Temporally and Spatially Dependent Flow

In the present study, analytical solutions are obtained for two-dimensional advection dispersion equation for conservative solute transport in a semi-infinite heterogeneous porous medium with pulse type input point source of uniform nature. The change in dispersion parameter due to heterogeneity is considered as linear multiple of spatially dependent function and seepage velocity whereas seepag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 1996