Highly sensitive and selective amperometric microbial biosensor for direct determination of p-nitrophenyl-substituted organophosphate nerve agents.
نویسندگان
چکیده
We report herein a whole cell-based amperometric biosensor for highly selective, highly sensitive, direct, single-step, rapid, and cost-effective determination of organophosphate pesticides with a p-nitrophenyl substituent. The biosensor was comprised of a p-nitrophenol degrader, Pseudomonas putida JS444, genetically engineered to express organophosphorus hydrolase (OPH) on the cell surface immobilized on the carbon paste electrode. Surface-expressed OPH catalyzed hydrolysis of the p-nitrophenyl substituent organophosphorus pesticides such as paraoxon, parathion, and methyl parathion to release p-nitrophenol, which was subsequently degraded by the enzymatic machinery of P. putida JS444. The electrooxidization current of the intermediates was measured and correlated to the concentration of organophosphates. The best sensitivity and response time were obtained using a sensor constructed with 0.086 mg dry weight of cells operating at 600 mV applied potential (vs Ag/AgCl reference) in 50 mM citrate--phosphate pH 7.5 buffer with 50 microM CoCl2 at room temperature. Under optimum operating conditions the biosensor measured as low as 0.28 ppb of paraoxon, 0.26 ppb of methyl parathion, and 0.29 ppb parathion. These detection limits are comparable to cholinesterase inhibition-based biosensors. Unlike the inhibition-based format, this biosensor manifests a selective response to organophosphate pesticides with a p-nitrophenyl substituent only, has a simplified single-step protocol with short response time, and can be used for repetitive/multiple and on-line analysis. The service life of the microbial amperometric biosensor was 5 days when stored in the operating buffer at 4 degrees C. The new biosensor offers great promise for rapid environmental monitoring of OP pesticides with nitrophenyl substituent.
منابع مشابه
Microbial biosensor for direct determination of nitrophenyl-substituted organophosphate nerve agents using genetically engineered Moraxella sp.
A microbial biosensor consisting of a dissolved oxygen electrode modified with the genetically engineered PNP-degrader Moraxella sp. displaying organophosphorus hydrolase (OPH) on the cell surface for sensitive, selective, rapid and direct determination of p-nitrophenyl (PNP)-substituted organophosphates (OPs) is reported. Surface-expressed OPH works in tandem with the PNP oxidation machinery o...
متن کاملWhole cell-enzyme hybrid amperometric biosensor for direct determination of organophosphorous nerve agents with p-nitrophenyl substituent.
In this paper, we reported the construction of a hybrid biosensor for direct, highly selective, sensitive, and rapid quantitative determination of organophosphate pesticides with p-nitrophenyl substituent using purified organophosphorus hydrolase (OPH) for the initial hydrolysis and Arthrobacter sp. JS443 for subsequent p-nitrophenol oxidation. The biocatalytic layer was prepared by co-immobili...
متن کاملAmperometric microbial biosensor for direct determination of organophosphate pesticides using recombinant microorganism with surface expressed organophosphorus hydrolase.
An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parat...
متن کاملFlow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents.
A flow injection amperometric biosensor for the determination of organophosphate nerve agents was developed. The biosensor incorporated an immobilized enzyme reactor that contains the enzyme organophosphorus hydrolase covalently immobilized on activated aminopropyl controlled pore glass beads and an electrochemical flow-through detector containing carbon paste working electrode, a silver/silver...
متن کاملRemote Biosensor for In-Situ Monitoring of Organophosphate Nerve Agents
A remote electrochemical biosensor for ®eld monitoring of organophosphate nerve agents is described. The new sensor relies on the coupling of the effective biocatalytic action of organophosphorus hydrolase (OPH) with a submersible amperometric probe design. This combination results in a fast, sensitive, selective, and stable response at large sample-instrument distances. Such attractive perform...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental science & technology
دوره 39 22 شماره
صفحات -
تاریخ انتشار 2005