Charge collection and radiation hardness of a SOI microdosimeter for medical and space applications.

نویسندگان

  • P D Bradley
  • A B Rosenfeld
  • K K Lee
  • D N Jamieson
  • G Heiser
  • S Satoh
چکیده

The first results obtained using a SOI device for microdosimetry applications are presented. Microbeam and broadbeam spectroscopy methods are used for determining minority carrier lifetime and radiation damage constants. A spectroscopy model is presented which includes the majority of effects that impact spectral resolution. Charge collection statistics were found to substantially affect spectral resolution. Lateral diffusion effects significantly complicate charge collection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation hardness and charge collection in a SOI based diode array designed for medical microdosimetry

 The radiation hardness of diode array devices based on silicon on insulator technology and bulk technology was investigated. The devices were exposed to 24 GeV/c protons (at CERN) up to a fluence of 4.1 10 p/cm. Charge collection following irradiation indicated a significant reduction in minority carrier lifetime. The damage constant was calculated using alpha particle spectroscopy methods. T...

متن کامل

Determination of Dose-Equivalent Response of A Typical Diamond Microdosimeter in Space Radiation Fields

Introduction: Microdosimeters are helpful for dose equivalent measurement in unknown radiation fields. The favorable physical and mechanical properties of the detector-grade chemical vapor deposition diamond materials have made the diamond microdosimeters suitable candidate for radioprotection applications in space. The purpose of this work is the investigation of the dose equivalent response o...

متن کامل

Large area silicon microdosimeter for dosimetry in high LET space radiation fields: Charge collection study

Silicon microdosimeters for the characterisation of mixed radiation fields relevant to the space radiation environment have been under continual development at the Centre for Medical Radiation Physics for over a decade. These devices are useful for the prediction of single event upsets in microelectronics and for radiation protection of spacecraft crew. The latest development in silicon microdo...

متن کامل

First Silicon Microdosimeters Based on Cylindrical Diodes

Silicon detectors are used in many medical applications for particle tracking, X-ray medical imaging, gamma or X-ray spectrometry, among others. The development of new silicon detectors for specific physics areas leads to overcome technological challenges that means not only optimize the design, but also improve the micro-fabrication processes. A new design of a solid-state-detector based on si...

متن کامل

Radiation-hard Layout Structures on Bulk and SOI Process by Device-level Simulations

This paper analyze the soft error tolerance related to layout structures on 65-nm bulk and SOI processes. The layout structure in which well contacts are placed between redundant latches suppresses MCU effectively. Also the tolerance of SOI structure transistor is estimated by TCAD simulations. The charge collection mechanism is suppressed by the BOX (Buried Oxide) in SOI transistor. Charge sha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on nuclear science

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 1998