Charge collection and radiation hardness of a SOI microdosimeter for medical and space applications.
نویسندگان
چکیده
The first results obtained using a SOI device for microdosimetry applications are presented. Microbeam and broadbeam spectroscopy methods are used for determining minority carrier lifetime and radiation damage constants. A spectroscopy model is presented which includes the majority of effects that impact spectral resolution. Charge collection statistics were found to substantially affect spectral resolution. Lateral diffusion effects significantly complicate charge collection.
منابع مشابه
Radiation hardness and charge collection in a SOI based diode array designed for medical microdosimetry
The radiation hardness of diode array devices based on silicon on insulator technology and bulk technology was investigated. The devices were exposed to 24 GeV/c protons (at CERN) up to a fluence of 4.1 10 p/cm. Charge collection following irradiation indicated a significant reduction in minority carrier lifetime. The damage constant was calculated using alpha particle spectroscopy methods. T...
متن کاملDetermination of Dose-Equivalent Response of A Typical Diamond Microdosimeter in Space Radiation Fields
Introduction: Microdosimeters are helpful for dose equivalent measurement in unknown radiation fields. The favorable physical and mechanical properties of the detector-grade chemical vapor deposition diamond materials have made the diamond microdosimeters suitable candidate for radioprotection applications in space. The purpose of this work is the investigation of the dose equivalent response o...
متن کاملLarge area silicon microdosimeter for dosimetry in high LET space radiation fields: Charge collection study
Silicon microdosimeters for the characterisation of mixed radiation fields relevant to the space radiation environment have been under continual development at the Centre for Medical Radiation Physics for over a decade. These devices are useful for the prediction of single event upsets in microelectronics and for radiation protection of spacecraft crew. The latest development in silicon microdo...
متن کاملFirst Silicon Microdosimeters Based on Cylindrical Diodes
Silicon detectors are used in many medical applications for particle tracking, X-ray medical imaging, gamma or X-ray spectrometry, among others. The development of new silicon detectors for specific physics areas leads to overcome technological challenges that means not only optimize the design, but also improve the micro-fabrication processes. A new design of a solid-state-detector based on si...
متن کاملRadiation-hard Layout Structures on Bulk and SOI Process by Device-level Simulations
This paper analyze the soft error tolerance related to layout structures on 65-nm bulk and SOI processes. The layout structure in which well contacts are placed between redundant latches suppresses MCU effectively. Also the tolerance of SOI structure transistor is estimated by TCAD simulations. The charge collection mechanism is suppressed by the BOX (Buried Oxide) in SOI transistor. Charge sha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on nuclear science
دوره 45 6 شماره
صفحات -
تاریخ انتشار 1998