Inadvertent arterial insertion of a central venous catheter: delayed recognition with abrupt changes in pressure waveform during surgery -A case report-
نویسندگان
چکیده
We present a case of inadvertent arterial insertion of a central venous catheter, identified during a pericardiectomy procedure after observing abrupt changes in pressure waveform and confirmed via arterial blood gas analysis and transesophageal echocardiography. Central venous pressure measurement was initially 20 mmHg in supine, and then elevated to 30-40 mmHg in right lateral decubitus, presumably resulting from constrictive physiology of pericarditis. The pressure waveforms, however, abruptly changed from a venous to an arterial waveform during surgery. When visual discrimination between arterial and venous blood regurgitation is unreliable, anesthesiologists should confirm that using all the available methods one has on the scene, especially after at least two unsuccessful attempts or in patients with advanced age or clinical conditions resulting in jugular venous dilation. To prevent arterial catheterization, one should limit the leftward rotation of the head by <40° and consider using ultrasound-guided method after more than two unsuccessful attempts.
منابع مشابه
Arterialization of central venous pressure waveform
due to catheter migration has been reported.[3] Arterial waveform showed by a CVC generally indicates inadvertent arterial insertion.[4] Accidental position of CVC in the left internal thoracic vein or the pericardiophrenic vein mimicking as arterial waveform has also been reported.[5] The author concluded the “arterial” waveform by CVC was due to transmission of pulse waves of adjacent cardiac...
متن کاملUltrasound detection of guidewire position during central venous catheterization.
INTRODUCTION Ultrasound guidance decreases complications of central venous catheter (CVC) placement, but risks of arterial puncture and inadvertent arterial catheter placement exist. Ultrasound-assisted detection of guidewire position in the internal jugular vein could predict correct catheter position before dilation and catheter placement. METHODS Ultrasound examinations were performed in a...
متن کاملUnexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report
BACKGROUND Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct th...
متن کاملA catheter malpositioned patient with pain and paresthesia
We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...
متن کاملManagement of Catheter Induced Upper Limb Suppurative Thrombophlebitis in a Patient after Coronary Artery Bypass Graft Surgery: a Case Report
Introduction: One of the important complications of peripheral venous catheters is suppurative thrombophlebitis that would be life threatening without treatment. In this report, we introduce a patient who developed purulent thrombophlebitis due to venous catheter in the upper limb after coronary artery bypass graft surgery. Multiple abscess formation was developed on her upper limb after the th...
متن کامل