Flow injection conductometric system with gas diffusion separation for the determination of Kjeldahl nitrogen in milk and chicken meat.

نویسندگان

  • Jaroon Junsomboon
  • Jaroon Jakmunee
چکیده

A simple flow injection (FI) conductometric system with gas diffusion separation was developed for the determination of Kjeldahl nitrogen (or proteins) in milk and chicken meat. The sample was digested according to the Kjeldahl standard method and the digest was diluted and directly injected into the donor stream consisting of 4M NaOH. In alkaline medium, ammonium was converted to ammonia, which diffused through the PTFE membrane to dissolve in an acceptor stream (water). Dissociation of ammonia caused a change in conductance of the acceptor solution, which was linearly proportional to the concentration of ammonium originally present in the injected solution. A conductometric flow through cell and an amplifier circuit was fabricated, which helped improve sensitivity of the conductometric detection system. With using a plumbing Teflon tape as a gas diffusion membrane and without thermostating control of the system, a linear calibration graph in range of 10-100mgL(-1) N-NH(4) was obtained, with detection limit of 1mgL(-1) and good precision (relative standard deviation of 0.3% for 11 replicate injections of 50mgL(-1) N-NH(4)). The developed method was validated by the standard Kjeldahl distillation/titration method for the analysis of milk and chicken meat samples. The proposed system had sample throughput of 35h(-1) and consumed much smaller amounts of chemical than the standard method (275mg vs 17.5g of NaOH per analysis, respectively).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kjeldahl nitrogen analysis as a reference method for protein determination in dairy products.

Measurement of total nitrogen by Kjeldahl analysis is the historical reference method for determination of the protein content of dairy products and is used for both calibration and validation of alternative methods for protein determination. Accurate evaluation of alternative methods is not possible if there is large uncertainty regarding the reference values. When Kjeldahl analysis is used to...

متن کامل

Mathematical Modeling of Gas Separation Process with Flat Carbon Membrane

Carbon molecular sieve membranes (CMSMs) have been considered as very promising candidates for gas separation, in terms of separation properties as well as thermal and chemical stability. Due to the numerous advantages and wide applications of carbon membranes, their application for gas separation is of special importance. Because of the importance of carbon membranes and a large number of stud...

متن کامل

Energy Consumption Analysis and Effect of Broiler Chicken Capacity on Energy Indices (A Case Study in Alborz Province)

With increasing population, demand for chicken meat has increased and resource constraints have led to increased production with an emphasis on improving the productivity of inputs and energy indices, so studying energy consumption in broiler production is important. One of the important issue in broiler industry is energy consumption. In this study, energy consumption flow and amount of energy...

متن کامل

Determination of Carbadox and Olaquindox Residues in Chicken Muscles, Chicken Liver, Bovine Meat, Liver and Milk by MLC with UV Detection: Application to Baby Formulae

A simple and sensitive method was optimized and validated for the analysis of carbadox and olaquindox residues in chicken muscles, chicken liver, bovine meat, liver and milk. Analytical separation was performed in less than 4 min using a C18 column with UV detection at 373 nm and a micellar solution of 0.1 M sodium dodecyl sulphate, 10 % acetonitrile and 0.3 % triethylamine in 0.02 M phosphoric...

متن کامل

A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: Spectrophotometric determination of ammonium.

A flow system with a multi-channel peristaltic pump placed before the solenoid valves is proposed to overcome some limitations attributed to multi-commuted flow injection systems: the negative pressure can lead to the formation of unwanted air bubbles and limits the use of devices for separation processes (gas diffusion, dialysis or ion-exchange). The proposed approach was applied to the colori...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 627 2  شماره 

صفحات  -

تاریخ انتشار 2008