Trimethoprim interferes with serum methotrexate assay by the competitive protein binding technique.

نویسندگان

  • K Hande
  • J Gober
  • R Fletcher
چکیده

Administration of Bactrim (a combination of trimethoprim and sulfamethoxazole) to a patient who also was receiving methotrexate caused a significant increase in apparent plasma methotrexate concentrations as determined by competitive protein binding assay with use of dihydrofolate reductase (EC 1.5.1.3) from Lactobacillus casei as the binding protein. This spurious increase was caused by trimethoprim in the patient's plasma. A plasma trimethoprim concentration of 0.1 mg/L inhibited binding of radiolabeled methotrexate to dihydrofolate reductase by 50%. In contrast, radioimmunoassay for methotrexate was not affected by concomitant administration of trimethoprim. The competitive protein binding assay for methotrexate should not be used in patients being treated with Bactrim or Septra (a similar combination). However, the L. casei competitive protein binding assay technique can be used to assay plasma trimethoprim concentrations with sensitivity to 0.02 mg of trimethoprim per liter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A microbiological assay for the measurement of methotrexate in biological fluids.

A microbiological assay for the measurement of methotrexate has been designed, using a chloramphenicol resistant mutant of Lactobacillus casei as the test organism. The method is simple, precise and inexpensive. Results are not significantly different from those obtained using a methotrexate radioassay kit employing a competitive protein binding technique. However, where patients are being trea...

متن کامل

Monitoring methotrexate in clinical samples from cancer patients during chemotherapy with a LSPR-based competitive sensor.

A competitive binding assay based on localized surface plasmon resonance (LSPR) of folic acid-functionalized gold nanoparticles (FA-AuNPs) and human dihydrofolate reductase enzyme (hDHFR) was developed to detect nanomolar to micromolar concentrations of the widely applied anti-cancer drug, methotrexate (MTX). By the nature of the competitive assay for MTX, the LSPR shift from specific binding b...

متن کامل

Fluoxetin Competes with Cortisol for Binding to Human Serum Albumin

Human serum albumin (HSA) is an important protein that carries variety of substances like some hormones and drugs in blood. Pharmacological studies of the interaction of many drugs and HSA are reported during several decades, specially recently years. Interaction of cortisol and fluoxetine hydrochloride (FLX) (as a common anti-stress drug) with HSA (as their carrier in blood) has been studied s...

متن کامل

Fluoxetin Competes with Cortisol for Binding to Human Serum Albumin

Human serum albumin (HSA) is an important protein that carries variety of substances like some hormones and drugs in blood. Pharmacological studies of the interaction of many drugs and HSA are reported during several decades, specially recently years. Interaction of cortisol and fluoxetine hydrochloride (FLX) (as a common anti-stress drug) with HSA (as their carrier in blood) has been studied s...

متن کامل

Enzyme immunoassay and enzyme inhibition assay of methotrexate, with use of the centrifugal analyzer.

Methotrexate was determined by the homogeneous enzyme immunoassay (EMIT) with the Multistat and CentrifiChem centrifugal analyzers and by the enzyme inhibition assay with use of the Multistat centrifugal analyzer. With both methods, the standard curve extends from 0.2 to 2.0 mumol/L and there is no interference from bilirubin in concentrations up to 100 mg/L. Moderately lipemic samples do not i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 11  شماره 

صفحات  -

تاریخ انتشار 1980