Double-sampled echo-planar imaging at 3 tesla.
نویسندگان
چکیده
A persistent artifact in the images acquired by the echo-planar imaging (EPI) method is the Nyquist or N/2 ghost which interferes with the image and reduces the signal-to-noise ratio (SNR). The Nyquist ghost is the result of the time-reversal asymmetry between the even and odd echoes. To eliminate this artifact, the authors present a double-sampled EPI (DSEPI) method in which echoes from each even and odd echo pair are equally phase encoded. The even and odd echoes are separately reconstructed into two distinct images which are then added together. The DSEPI method has been applied to human brain at 3.0 T and shown to be a simple and effective way to eliminate the Nyquist ghost and restore image SNR loss.
منابع مشابه
Sensitivity Encoded Proton Echo Planar Spectroscopic Imaging (PEPSI) in Human Brain at 7 Tesla
choline, glutamate and inositol (32x32 matrix) with 2-fold SENSE acceleration. Fig.3 Fully sampled PEPSI maps of non-suppressed water (64x64 matrix) and metabolite maps of NAA, creatine, choline, glutamate and inositol (32x32 matrix), acquired in 8.5 min with 0.63 cc voxel size. Fig.1 Non-water-suppressed PEPSI maps on phantom at 7 T show good reconstruction performance for up to 4-fold acceler...
متن کاملDiffusion tensor imaging of the kidney at 3 Tesla MRI: normative values and repeatability of measurements in healthy volunteers.
PURPOSE To evaluate the feasibility of renal diffusion tensor imaging and determine the normative fractional anisotropy and apparent diffusion coefficient values at 3 Tesla magnetic resonance imaging (MRI) using parallel imaging and free breathing technique. MATERIALS AND METHODS A total of 52 young healthy volunteers with no history of renal disease were included in the study. MRI examinatio...
متن کاملHigh Spatial Resolution Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) in Human Brain at 3 Tesla using 32-Channel RF Coil Array
15 mm PEPSI slice) and metabolic images of mI, Cho, Cr+PCr, Glu+Gln, NAA+NAAG and macromolecules at 0.9 ppm (MM09) measured with 0.25 cc spatial resolution, (left) before and (right) after partial volume and relaxation correction. Cho, Cr+PCr and Glu+Gln maps show strong GM/WM contrast and considerable anatomical detail, including sulcal structure (see red and yellow arrows). Fig.1:Selected cen...
متن کاملScan time reduction for readout‐segmented EPI using simultaneous multislice acceleration: Diffusion‐weighted imaging at 3 and 7 Tesla
PURPOSE Readout-segmented echo-planar imaging (rs-EPI) can provide high quality diffusion data because it is less prone to distortion and blurring artifacts than single-shot echo-planar imaging (ss-EPI), particularly at higher resolution and higher field. Readout segmentation allows shorter echo-spacing and echo train duration, resulting in reduced image distortion and blurring, respectively, i...
متن کاملDiffusion Weighted Imaging at 7T with STEAM-EPI and GRAPPA
Introduction: Diffusion Imaging at 7 Tesla has been quite a challenge. Standard diffusion sequences require long time to play diffusion gradients, especially for high b-values. This compromises higher intrinsic SNR [1]at 7T with shorter T2 relaxation. At 7T twice refocused spin echo [2] used for standard diffusion weighted imaging also suffers from high SAR. Magnetic field inhomogeneities that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance. Series B
دوره 113 2 شماره
صفحات -
تاریخ انتشار 1996