Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula

نویسندگان

  • Marianella Sierraalta
  • Jose L. Vivas
  • Michael E. Razzoog
  • Rui-Feng Wang
چکیده

Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single edentulous CAD/CAM surgical guide were separated in two groups and resin patterns simulating the framework for a fixed complete denture developed. Five casts were sent to dental laboratories to invest, cast in a Palladium-Gold alloy and fit the framework. Ten casts had the resin pattern scanned for fabrication of milled bars in Titanium. Using measuring software, positions of implant replicas in the definitive model were recorded. The three dimensional spatial orientation of each implant replica was matched to the implant replica. Results. Results demonstrated the mean vertical gap of the Cast framework was 0.021 (+0.004) mm and 0.012 (0.002) mm determined by fixed and unfixed best-fit matching coordinate system. For Titanium frameworks they were 0.0037 (+0.0028) mm and 0.0024 (+0.0005) mm, respectively. Conclusions. Milled one-piece Titanium fixed complete denture frameworks provided a more accurate precision of fit then traditional cast frameworks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The precision of fit of cast and milled full-arch implant-supported restorations.

PURPOSE The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cas...

متن کامل

Volumetric determination of the amount of misfit in CAD/CAM and cast implant frameworks: a multicenter laboratory study.

PURPOSE The purposes of this study were (1) to evaluate the fit between implant frameworks and implants fabricated with two types of implant framework fabrication techniques: computer-aided design/computer-assisted machining (CAD/CAM) and conventional casting with the lost wax technique; and (2) to describe a digital measurement system consisting of tactile scanning and computer software progra...

متن کامل

A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks.

STATEMENT OF PROBLEM An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps. PURPOSE The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by ce...

متن کامل

Implant/abutment vertical misfit of one-piece cast frameworks made with different materials.

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was meas...

متن کامل

On cobalt-chrome frameworks in implant dentistry.

BACKGROUND Cobalt-chrome (CoCr) alloys have been used in dentistry in decades but very little is known about their behavior and biological impact as framework materials in implant dentistry. Furthermore, few studies have evaluated and compared the clinical and radiological results of abutment and abutment-free implant treatment concepts. AIMS To investigate in vitro CoCr and commercially pure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012